T5 Linear fluorescent lamp, a new generation lighting sources, will replace T8/T10/T12 because of its excellent performance and advantages. Here we introduce an electronics T5 system which can update the old magnetic T8/T10/T12 system easily, this will meet the requirement of the Energysaving Lighting Reconstructing Program all over the world.:
The system includes one IEC standard T5 Tri-phosphor fluorescent tube and one build-in ballast fixture with G13 pin base. The system meets IEC standard T8/T10/T12 in size and base. Can install in magnetic T8/T10/T12 fixtures directly.
Why replace T8(T10, T12)lamp with this special T5 converter?
Here are the reasons:
1. Comparing with magnetic T8(T10, T12), it will save 35-50% electricity which save power bill by 35-50%.
2. No need to change anything on the original fixture.
3. Easy installation, the replacing procedures are the same as replacing a normal tube. Will much save the labor cost of Energysaving Lighting Reconstructing Program.
4. Power factor improved from 0.5(traditional magnetic ballast) to >0.95. The current decreases by 3-5 times which will help to reduce the wastage of electricity system and thus save energy.
5. Rapid start without flickering, even under low temperature or low voltage.
6. CRI>80, get better color performance.
7. Hi frequency electronic ballast, protecting eyes from 50Hz flickering of light caused by magnetic ballasts.
8. Noises free.
9. Reduce heat during operation. It indirectly saves energy because it helps to decrease the load of air-conditioning system.
10. Complete abnormal protection function prevent from burning on accident, life end or gas leak etc.
11. The fixture reflector can distribute the light to right direction, improve the system efficiency and then save more energy.
How to replace:
1. Turn off power supply
2. Take away the T8 Lamp
3. Take away the starter
4. Take away the rectify capacitor, if not, the power factor of the capacitor will be reduced to 0.5
5. Install the T5 lamp tube what in a same way of T8 Lamp
6. Turn on the power, then finish the installation.
Product Specification:
1. Power factor: 0.95
2. THD: ≤ 10%
4. EMC: Not passed
5. Dielectric strength: Can stand 1500V for one minute without electrical breakdown. 6. Insulating Resistance: ≥ 100MΩ
7. Abnormal protection: YES
8. Surface temperature rise: ≤ 25K
9. Leakage Current: Below 1mA
10. Wire is 0.25mm2
11. The ballast and tube can start while put in the fridge at -10 degree when input with rated voltage.
12. The ballast and tube can work well for 2 hours at 100 degree oven and no components is over heated.
13. Imitating the tube can not start, turn on and off the ballast for 100 times, there is not any damage to the ballast.
14. The average life for the ballast is 2 years, and quality guarantee is 2 years. The tube life time is 15000hours.