The features of linear grating:
Advanced optical measuring system. The proven five bearings supporting design is used in the slide carrier of PR series transducer , which have been proven to be the most reliable mechanical system design for slide carrier of optical grating linear transducer.
Advanced optical measuring system. The proven five bearings supporting design is used in the slide carrier of PR series transducer , which have been proven to be the most reliable mechanical system design for slide carrier of optical grating linear transducer.
| PR-S | PR-M | PR-S | PR-M | PR-L | |
| Optical grating steps | 20vm(0.02mm) | ||||
| Slide carrier system | transmissive infrared system-wavelength:880mm | ||||
| Resolution (vm) | 5 | 5 | 1 | 1 | 5 |
| Measurement length(50-500mm) | every 50mm per length specification | ||||
| Accuracy (50-500mm) (vm) | ±6 | ±6 | ±4 | ±4 | |
| 550-1000mm (vm) | ±10 | ±10 | ±8 | ±8 | |
| 1100-1500mm (vm) |
|
||||
| 1600-2000mm (vm) |
|
||||
| 2100-3000mm (vm) |
|
||||
| Repeatability (vm) | 3 | 3 | 2 | 2 | 5 |
| Operating temperature | temperature:0-50℃ Moisture:≤90 | ||||
| Power supply | DC 5V±5% | ||||
| Output sign | TTL | TTL | EIA-422-A | TTL | TTL |