Product Main

Specifications

The HT5156 is a bench-typedual-display digital multimeter with a price well worth its value. It provides a broad range of features and measurement functions which meet various requirements in manufacturing and R&D environments.
 
The 600,000 counts HT5156 provides real-time measuring and readback function. It also features high brightness/contract VFD4-wire resistance measurement technique and 0.02% DCV measuring accuracy. For those who need to control and take preset measurements with a PC, the built-in USB and RS-232C interfaces provide an easy connection between the PC and DMM. The USB and RS-232C interfaces can be controlled remotely via industry standard SCPI commands, which ensure an easy integration with different programming environments.
 
 
Product Features:
l   600,000 Counts Display
l   22 Built-in Measurement Function  DCV, ACV, DC+ACV, DCI, ACI, DC+ACI, 2Wohm, 4Wohm, Diode Test, Continuity Beeper, Capacitance, Frequency, Period. %Duty Cycle, Temperature, dB, dBm, Math(MX+B, %, 1/X), MAX/MIN, Auto Hold, REL, Compare
l   Auto or Manual Ranging
l   VFD Dual Display
l   0.02% DCV Accuracy
l   ACV Measuring Frequency Up to 100KHz
l   Current Measurement Range with High Energy Fuse Protection
l   AC or AC+DC True RMS
l   2000 Points Data-Logging Function
l   Selectable Measurement Rate
l   External Trigger Function
l   Standard RS-232C and USB interface
l   Option: GPIB(IEEE-488.2) interface
 
Electrical Specifications
Accuracy is ±(% reading digits + number of digits) or otherwise specified, at 23°C ± 5°C & less than 75% relative humidity. True RMS voltage & current accuracies are specified from 5 % to 100 % of range or otherwise specified. Maximum Crest Factor < 1.8:1 at full scale & < 3.6:1 at half scale, and with frequency components within the specified frequency bandwidth for non-sinusoidal waveforms.
 
DCV 
Range                                                               Accuracy
600.000 mV, 6.00000V, 60.0000V              0.02%+20d
600.000V                                                         0.04%+20d
1000.00V                                                         0.05%+20d
Input Impedance: 10Mohm
 
DC Current
Range                                              Accuracy                               Burden Voltage
600.000mA                                     0.15%+200d                        0.11mV/mA(typical)
6000.00mA                                     0.1%+200d
60.0000mA                                     0.15%+200d                         1.8mV/mA(typical)
600.000mA                                     0.15%+300d
6.00000A                                                0.5%+200d                           26mV/A(typical)
10.0000A 1)                                    0.5%+200d
 1) ≤10A continuous, >10A ~ 20A for 30 second max with 5 minutes cool down interval
 
True RMS AC & AC+DC Voltage
Range                                                      Accuracy 1)
20Hz -- 45Hz
600.000mV, 6.00000V, 60.0000V          1.5%+600d
600.000V, 1000.00V                               Unspec'd
45Hz -- 300Hz
600.000mV                                             0.3%+200d
6.00000V, 60.0000V                               0.8%+200d
600.000V, 1000.00V                               0.4%+400d
                                300Hz -- 5kHz
600.000mV                                            0.3%+100d
6.00000V, 60.0000V, 600.000V            0.4%+400d
1000.00V  (when 300Hz ~ 1kHz only)     0.8%+400d
 
5kHz -- 20kHz
600.000mV                                     0.5%+200d
6.00000V, 60.0000V                       0.8%+200d
600.000V                                                0.5%+200d
1000.00V                                                Unspec'd
 
20kHz -- 100kHz
600.000mV                                     2.5%+400d
6.00000V, 60.0000V                       4.0%+400d 2)
600.000V                                                Unspec'd
1000.00V
1) From 5% to 10% of range: accuracy % of reading (or in dB) + 1800d
2) From 10% to 15% of range: accuracy % of reading (or in dB) + 1000d
Input Impedance: 10Mohm, 50pF nominal (80pF nominal for 500mV range).
 
True AC & AC+DC Current
Range                                     Accuracy                                 Burden Voltage
50Hz – 60Hz
600.000uA                             0.5%+500d                             0.11mV/uA(typical)
6000.00uA                            0.5%+500d                              0.11mV/uA(typical)
60.0000mA                           0.5%+500d                              1.8mV/mA(typical)
600.000mA                           0.5%+500d                              1.8mV/mA(typical)
6.00000A                               0.5%+500d                               26mV/A(typical)
10.0000A 1)                          0.5%+500d                               26mV/A(typical)
40Hz – 1kHz
600.000uA                             0.7%+500d                           0.11mV/uA(typical)
6000.00uA                             0.7%+500d                           0.11mV/uA(typical)
60.0000mA                            0.7%+500d                          1.8mV/mA(typical)
600.000mA                            0.7%+500d                          1.8mV/mA(typical)
6.00000A                                0.7%+500d                           26mV/A(typical)
10.0000A 1)                           0.7%+500d                           26mV/A(typical)
1kHz – 10kHz
600.000uA                             2.0%+500d                           0.11mV/uA(typical)
6000.00uA                             2.0%+500d                           0.11mV/uA(typical)
60.0000mA                            2.0%+500d                           1.8mV/mA(typical)
600.000mA                            2.0%+500d                           1.8mV/mA(typical)
6.00000A                                  Unspec'd                            26mV/A(typical)
10.0000A 1)                             Unspec'd                            26mV/A(typical) 
1) ≤10A continuous, >10A ~ 20A for 30 second max with 5 minutes cool down interval
 
Ohms (2W, 4W)
Range                                                      Accuracy
600.000ohm                                          0.07%+20d
6.00000kohm                                        0.07%+20d
60.0000kohm                                        0.1%+20d
600.000kohm                                        0.1%+20d
6.00000ohm                                          0.5%+60d
60.0000Mohm                                       2.0%+60d
Open Circuit Voltage: 1.2VDC typically (3VDC typically for 500ohm range)
1)From 0% to 10% of range: Specified accuracy + 30d
 
Diode Tester
Range                      Accuracy              Test Current                Open Circuit Voltage
2.00000V                  1%+10d                  0.4mA (Typical)            3.5 VDC (Typical) 
 
Continuity Beeper
Range                                                      Accuracy 
600.000ohm                                      0.07%+90d+xohm 

Capacitance
Range                              Accuracy 1)
60.000nF                         0.8%+30d
600.00nF                         0.8%+30d  
6.0000uF                        1.5%+30d
60.000uF                        2.5%+30d
600.00uF                        3.5%+50d
9.9999mF                        5.0%+50d 
 1) Accuracies with film capacitor or better
 
Hz Line Level Frequency
Function Range           Sensitivity (Sine RMS)             Measurement Range
600mV                                 100mV                         10Hz ~ 200kHz
6V                                           0.6V                                              10Hz ~ 200kHz
60V                                         6V                                                 10Hz ~ 100kHz
600V                                       60V                                               10Hz ~ 100kHz
1000V                                     600V                                             10Hz ~ 10kHz
600uA, 6000uA                    300uA                                          10Hz ~ 10kHz
60mA, 600mA                        30mA                                            10Hz ~ 10kHz
6A, 10A                                  3A                                                 10Hz ~ 3kHz
Accuracy: 0.02%+4d
 
Hz Logic Level Frequency 
Range                                                                      Accuracy
5.0000Hz--1.00000MHz                                         0.002%+4d 
Sensitivity: 2.5Vp square wave
 
%Duty Cycle
Range                                                                      Accuracy
0.100% -- 99.990%                                                 3d/kHz+20d
Input Frequency:  5Hz -- 500 kHz, 5V Logic Family
 
 Temperature
Range                                                                      Accuracy
-100.0°C to 1000.0°C                                             0.3%+1.5°C
-148.0°F to 1832.0°F                                              0.3%+3.0°F
Thermocouple range & accuracy not included
 
 Math Functions
dB, dBm, Math(MX+B, %, 1/X), Max/Min(Max, Min, Max-Min, Avg),
REL, Hold, Compare, Filter, Store, Recall
Display                                                             5x7 dot matrix VFD Display
Interface                                                          Standard RS-232,USB. Optional GPIB(SCPI)
Power Source                                                AC100/110/220/230V,±10%,50/60Hz
Dimension & Weight                                     262(W)x104(H)x367(D)mm, Approx. 4.4Kg