Product Main

Specifications

USB powered support fold zoom Eloam handheld digital microscope C708 for antique, jewelers

Descrition:

Eloam Handheld Digital Microscope can be connected with computer and easy to operate. Using the additional ELOAM software, you can make picture capture and video recording easily.

Applications:

Eloam Handheld Digital Microscope has a wide scope of applications, such as:

1.Skin detection
2.Hair root detection
3.Industrial inspections (such as print PCB board, precise equipment)
4.Printing
5.Textile
6.Biologic inspection
7.Antique and Jewelers inspection
8.Crime scene, imprint and material evidence investigation
9.And more……

Specifications:

 

Model 

C708

Certificate 

CE, RoHs, FCC, SGS

Put a large number of times the free

1-500-fold zoom 

Recorded as 

Software,  high compression

Taking pictures

Software camera,  remote control camera 

Light source

Led lighting stepless adjustment ,  USB powered

Software measurement 

Curvature,  length , angle,  accuracy 1UM

Drawing software

Software can draw arc line,  the length of line,  angle line,  marked 

Input software

Software to enter text 

Maximum size 

lens diameter 7mm*length 126mm 

Pixels 

500 million

The image pixels 

2592*1944, 1280*960,

960*720, 640*480, 320*240

Image speed 

15-30 Ching/sec

Interface 

USB 2.0 interface

Pakage size 

185mm*125mm*70mm

Sales service

7 days replcement,  1 year warranty ( Buyer should pay for shipping fee.)

System Requirment:
The computers should be required as:
OS: Windows 98SE/Me/2000/XP, Win 98/98SE/VISTA (XP/VISTA --plug and play, it don’t need to install driver)
CPU: Pentium 233MHz&nbsp and above
Memory: 256MB SDRAM
Interface: USB 2.0
HDD storage space: 600MB and above

Componet:
1.The body of digital microscope (attached photos on hardware installation and User’s manual)
2.CD( for special function)
3.Tripod (for microscope using)
4.Desktop microscope adjustable-stand (optional)
 
Hardware installation and using:
1.Plug USB cable into PC
2.If need fix, please fix the body of microscope into the clip of the tri-pod (accurately operation, please choose professional microscope adjustable stand when accurately operation is needed), adjust the lens to the object inspected.
3.Choose the suitable distance between the stage and objects, adjust the focus.
4.Adjust the led light by touch button (not for all models) or light control

Safety precautions:
Do not touch the lens with finger to avoid electrostatic damage.
Do not attempt to disassemble this product yourself. Opening the convers may expose you to dangerous voltage points or other risks.
When hands are wet, do not plug in or remove the adaptor or other connectors.
Using or storing USB microscope, do not plug in any other cables.
Do not clean the products with ethyl alcohol or other organic solvent camera case, painted surfaces& lens.
If the lens is dirty, please use a kens brush on soft cloth to wipe clean. Avoid touching them with your fingers. Exercise care to avoid scratching the lens.
Without protection, do not put microscope outdoor to avoid the lens damaging by high temperature or humidity.
Temperature: 0°C~40°C and humidity: 45%~85%
If liquid has entered stage, immediately turn the power off and use dryer neither. Please send to the maintenance center
Using or storing USB microscope, need to watch all cables to avoid trip over.
To avoid electric shock. When remove all electric PC or TV. Please pull out the power source.

Difficulty resolution:

 

Items 

Trouble vision 

Reason 

Solution 

1

Blank screen 

1) LED is closed

2) Preview is closed 

3) No suitbale devices

4) Incorrect connection  with PC

1) Open LED

2)Open preview

3)Choose suitable devices

4)Connect USB again

2

1)Picture vague

2)Discoloration speed slow

1)Dirty lens

2)Incorrect focusing 

3)Incorrect connection with PC

4)The configuration of PC is too low 

1)Clean by lens paper

2)Adjust focusing 

3)Connect USB again

4)Choose new PC

3

Picture distortion 

1) Incorrect connection with PC

2) Trouble inside of microscope 

1) Connect USB again

2) Back to repair

4

Flicker picture 

Bad frequency

Choose the suitable frequency 

5

Can’t recognize 

1) Incorrect connection with PC

2) Trouble inside of microscope 

1)Connect USB again 

2)Back to repair

6

1) Touch reflect 2) slow,  no reflect 

1) Climate effect

2)Trouble inside of microscope 

1)Make the touch bottom 

humidity 

2) Back to repair