Product Main

Specifications

Advanced Ultrasonic Thickness Gauge (AUT500)
 

Key Features of Ultrasonic Thickness Gauge:

Live A-scan mode and B-can  

  0.01mm (0.001 in) resolution

Differential mode:
Reduction rate mode
Min/ Max mode
Alarm mode
Outline/ Filled rectification waveform
Update rate: 4MHz, 8MHz, scanning
Live A-scan with Waveform Adjust

This AUT500 Live A-scan mode allows users to view the ultrasound waveform (or A-scan) directly on the gauge's display, verify the thickness measurement, and make manual adjustments to gain and blanking settings to maximize measurement performance in challenging application. This helpful option features Manual Gain Adjust, Extended Blanking, Echo Blank Range, Gate, and Delay.

Gain Adjust

This feature is very helpful when making measurements on sound- attenuating materials such as cast metals. Manual Gain Adjust can be configured in 1-dB or 6-dB increments (Live A-scan mode only)

Extended Blanking

Allows blanking unwanted echoes due to material surface noise caused by rough or irregular surface (Live A-scan mode only)

Encoded B-scan option

B-scan display the cross section of test material. The waveform at the minimum thickness location is captured.

Thru Coat Capability (Optional)

In Echo- Echo mode, it could have thru coating capability. The paint thickness is up to 10mm.

Range

Adjustment of manual range control or auto zoom tracking to center echoes independent of selected range.

Rectification Mode
RF, Half wave positive, half wave negative and Full wave rectification.

Alarm Mode

Programmable Hi- Low alarm set point with audible and visual indicators.

Reduction Rate Measurement 

Displays thickness and percent difference between actual measurement and reference value.

Min/ Max Mode

Displays current thickness, minimum or maximum thickness depending on setting.

Differential Mode

Displays the difference from the actual thickness measurement and a user entered reference value.

Transducers:

AUT500 Probe/Transducer Specifications

 

Model PT08

Model PT06

Model PT04

Model ZT12

Model GT12

Probe Style

Standard

Small tube

Fingertip

Cast iron

High temperature

Frequency
5MHz
7.5MHz
10MHz
2MHz
5MHz

Contact Diameter

11mm
8mm
6mm
17mm
15mm
Range
0.8~100.0mm
0.8~30.0mm
0.5~20.0mm
4.0~508.0mm
4.0~80.0mm
Temperature
-10~70℃
-10~70℃
-10~70℃
-10~70℃
-20~300℃
 
Picture