Use in the situation of tension running. Motor will retain on certain torque. Able to use voltage to control torque speed's motor.
- Output from 3W to 40W.
- Suitable in the situation that objects must be rolled up.
- Ability to use in the situation of tension running.
- Output adjustment type is available.
- Insulation resistance: Use a DC500V high resistance gauge to measure the coil of motor and it's an outer shell when motor running in normal temperature and normal humidity, its value should be above 100MΩ.
- Insulation pressure endurance: Apply 60Hz, 1.5kV at the coil of motor and it's an outer shell for one minute without and extraordinary phenomenon when motor running in normal temperature and normal humidity.
- Temperature arises: Install two reduction gears or radiation plate of the same class at the motor. After rated running, test the coil by resistance method. Its value should be less than 75°C.
- Insulation Class: Class B (130°C).
- Overheat protection: Over heat shut down system.
- Environment temperature: -10°C~+50°C.
- Humid around the environment: Below 85% (No frosting happens).