Unique technical characteristics of equipment
All Information is Stored:
The system provides advanced full-information storage function, a complete record of the clinical testing information. A flexible testing process can be reproduced, in a dynamic real-time playback mode to adjust the gain, envelope, manual calculation. The maximum meets clinical needs.
Advanced M-wave mode:
Completely abandon the traditional model. From the 512-point FFT large image, doctors are able to freely observe the Doppler signal over the depth, arbitrary switching handy.
High sensitivity:
Application of digital technology makes the equipment work without ultrasound coupling agent even under 10% power. The image is still very clear and the power could be adjusted freely, making detection of elderly patients with no problems.
Powerful Case Management:
The system provides a case database management system.The network transmission function optional as per customers’ request.
Probe Conversion:
With the technology, using 4MHz continuous Doppler shift pulse Doppler detects extracranial blood vessels, superficial blood vessels more accurate.
Report Edit:
Based on powerful word document editing, free editiong, storage, access to and so on, the coexistence of a large number of diagnostic terminology, diagnosis.
Training: Graphic video of professional medical training software
Standard configurations:
V2.11 Doppler Systerm Software
Dedicated USB remote keyboard
Probe Frequency: 2MHz PW 4MHz CW
Spectrum scanning speed: 4s-12s can be arbitrarily adjusted
Maximum detection speed: ≥ 200cm /s
Transmit power: 10150mw(1-800% adjusted)
Spectrum display: more than 1000 colordisc
All information playback:>30h, synchronous spectrum image and voice
Automatically detect the display index: Vp Vm Vd PI RI SD MI HR TIC TIB
Frequency spectrum; 128point, 256 points, 512-point FFT
Supply Voltage: 220v±10% 50Hz±1Hz
Emboli detection: under single channel or dual channel model to monitor the emboli, fixing the emboli threshold.
Spindle wave technology
Monitoring trends images.
Optional Configurations:
Cerebral vascular stenosis and occlusion
Cerebrovascular atherosclerosis
Arteriovenous malformation
Hemorrhagic stroke, ischemic stroke
Vertigo and vertebral-basilar artery disease diagnosis
Transient ischemic attack
B) Preventive and Health Care:
Epidemiological study of brain blood vessel
Stroke prediction and the elderly health care
Cerebrovascular disease were long-term follow-up of
Evaluation of prognosis of stroke