Product Main

Specifications

The 0729-1759-99 inclinometer measures tilt angle and inclination in one or two axes with high accuracy and resolution. This inclinometer utilizes a Fredericks, dual axis, electrolytic tilt sensor and tilt sensor signal conditioner.
 
The Fredericks Dual/Two Axis RS-232 Digital Tilt Sensor Inclinometer is designed and manufactured in the United States of America at our facility in Huntingdon Valley, Pennsylvania. It includes a housed and potted Fredericks Signal Conditioner combined with a Fredericks Electrolytic Tilt Sensor with an environmental protection rating of IP66. The low profile of the housing and the analog interface combined with a competitive price make this tilt sensor inclinometer optimal for a variety of applications in many sectors where tilt angle measurement is required. Its features include the ability to: 
 
1.  Set zero position
2.  Output X and Y position through digital RS-232
3.  Output temperature through digital RS-232
4.  Set a timed output through digital RS-232 
 
Example Applications:
 
1.  Aerial lift platform level monitor or control
2.  Blade angle measurement of road graders and pavers
3.  Robotic controls
4.  Satellite dish alignment
5.  Navigation instrumentation and compensation
6.  Wheel alignment systems
 
Benefits: 
 
1.  Competitively priced
2.  Extremely long life
3.  Very low power consumption
4.  Excellent resolution, repeatability, and long term stability
5.  Excellent customer support
6.  On time deliveries
7.  Manufactured in The United States of America
 
Operating Specifications: 
 
Supply Voltage: +7 to +16 V dc
Output: Digital 16-bit (0 to 65535)
Operating Temperature: -40° to +70° C
Storage Temperature:  -40° to +70° C
Dimensions: 2.217" x 1.575" x 0.787" (L x W x H)
Mounting Holes: 0.138" diameter, 1.882" center to center
Temperature Sensor: -40° to +125° C with 10 bit resolution
 
RS-232 Digital Communication Specifications:
 
Baud Rate: 9600
Data Bits: 8
Parity: None
Stop Bits: 1 
 
RS-232 DIgital Commands:
 
'X' Output 16-bit X axis value (0 to 65535)
'Y' Output 16-bit Y axis value (0 to 65535)
'T' Output 10-bit temperature (0 to 1024)
'S' Start a timed output
'R' Reset the 'S' command (stop timed output)
'1' to '5' Set the delay for the 'S' command from 1 to 5 seconds, default is 1 second
'@' 'Z' '#' Save the current position as 0
'&' 'C' '*' Clear the saved 0 position
 
Physical Characteristics: 
 
56.3 mm x 40.00 mm x 16.00 mm (L x W x H)