| Brand Name: | fycables |
|---|---|
| Place of Origin: | China (Mainland) |
Quick Details
Specifications
Application: This product is applied to control, monitor and protect circuit with A.C. rated voltage up to 450/750V
450/750V PVC Insulated (Radiant XLPE Insulated) Control Cables
Conform to the Standard GB/T9330-2008
450/750V PVC Insulated (Radiant XLPE Insulated) Flam-retardant Control Cables
Conform to the Standard GB9330-2008
450/750V PVC Insulated (Radiant XLPE Insulated) Fire-resisting Control Cables
Conform to the StandardGB9330-2008/GB/T19666-2005
Type, Name and Application
|
Type |
Name |
Application |
|
|
PVC Insulated |
XLPE Insulated |
||
|
KVV [Z(S,B,C)-,N-] |
KYJV [Z(S,B,C)-,N-] |
Copper conductor PVC/Radiant XLPE Insulated, PVC sheathed Control Cable |
For laying fixed indoors, in cable ditch and piping |
|
KVVP [Z(S,B,C)-,N-] |
KYJVP [Z(S,B,C)-,N-] |
Copper conductor PVC/Radiant XLPE Insulated, copper wire braid shielded, PVC sheathed Control Cable |
For laying fixed indoors, in cable ditch and piping where shield is required |
|
KVVP2 [Z(S,B,C)-,N-] |
KYJVP2 [Z(S,B,C)-,N-] |
Copper conductor PVC/Radiant XLPE Insulated, copper tape shielded, PVC sheathed Control Cable |
For laying fixed indoors, in cable ditch and piping where shield is required |
|
KVV22 [Z(S,B,C)-,N-] |
KYJV22 [Z(S,B,C)-,N-] |
Copper conductor PVC/Radiant XLPE Insulated, Steel tape armored, PVC sheathed Control Cable |
For laying fixed indoors, in cable ditch, piping and directed in ground where can bear greater external mechanical force |
|
KVV23 [Z(S,B,C)-,N-] |
KYJV23 [Z(S,B,C)-,N-] |
Copper conductor PVC/Radiant XLPE Insulated, Steel tape armored, PE sheathed Control cable |
For laying fixed indoors, in cable ditch, piping and directed in ground where can bear greater external mechanical force |
|
KVV32 [Z(S,B,C)-,N-] |
KYJV32 [Z(S,B,C)-,N-] |
Copper conductor PVC/Radiant XLPE Insulated, fine Steel wire armored, PVC sheathed control cable |
For laying fixed indoors, in cable ditch, piping and directed in ground where can bear greater tensile mechanical force |
|
KVVP2-22 [Z(S,B,C)-,N-] |
KYJVP2-22 [Z(S,B,C)-,N-] |
Copper conductor PVC/Radiant XLPE Insulated, copper tape shielded, Steel tape armored, PVC sheathed control cable |
For laying fixed indoors, in cable ditch, piping and directed in ground where require shield environment and can bear greater external mechanical force |
|
KVVP22 [Z(S,B,C)-,N-] |
KYJVP22 [Z(S,B,C)-,N-] |
Copper conductor PVC/Radiant XLPE Insulated, copper wire shielded, Steel tape armored, PVC sheathed control cable |
For laying fixed indoors, in cable ditch, piping and directed in ground where require shield environment and can bear greater external mechanical force |
|
KVVR [Z(S,B,C)-,N-] |
KYJVR [Z(S,B,C)-,N-] |
Copper conductor PVC/Radiant XLPE Insulated, PVC sheathed soft control cable |
For laying indoors with flexibility and soft requirements |
|
KVVRP [Z(S,B,C)-,N-] |
KYJVRP [Z(S,B,C)-,N-] |
Copper conductor PVC/Radiant XLPE Insulated, copper wire braid shielded, PVC sheathed soft control cable |
For laying indoors with flexibility, soft and screen requirements |
Specification:
|
Type |
Conductor Nominal Cross Section |
|||||||
|
0.5 |
0.75 |
1.0 |
1.5 |
2.5 |
4 |
6 |
10 |
|
|
Cores |
||||||||
|
KVV, KVVP [Z(A,B,C)-, N-] KYJV, KYJVP [Z(A,B,C)-, N-] |
- |
2-61 |
2-14 |
2-10 |
||||
|
KVVP2 [Z(A,B,C)-, N-] KYJVP2 [Z(A,B,C)-, N-] |
- |
4-61 |
4-14 |
4-10 |
||||
|
KVV22, KVVP2-22 [Z(A,B,C)-, N-] KYJV22, KYJVP2-22 [Z(A,B,C)-, N-] KVV23, KVVP2-23 [Z(A,B,C)-, N-] KYJV23, KYJVP2-23 [Z(A,B,C)-, N-] KVVP22, KYJVP-22 [Z(A,B,C)-, N-] |
- |
7-61 |
4-61 |
4-14 |
4-10 |
|||
|
KVV32 [Z(A,B,C)-,N-] KYJV32 [Z(A,B,C)-,N-] |
- |
19-61 |
7-61 |
4-1 |
4-10 |
|||
|
KVVR [Z(A,B,C)-,N-] KYJVR [Z(A,B,C)-,N-] |
4-61 |
- |
- |
|||||
|
KVVRP [Z(A,B,C)-,N-] KYJVRP [Z(A,B,C)-,N-] |
4-61 |
4-48 |
- |
- |
||||