Product Main

Quick Details

Place of Origin: China (Mainland)
Model Number: MSLDR04
Brand Name: MSL
Properties: Medical X-ray Equipments & Accessories

Specifications

500ma x-ray machine | High Frequency X-ray Radiography System MSLDR04

High Frequency X-ray Radiography MSLDR04 System configuration 
                                  
High Frequency High Voltage X-ray Generator  MSLG50R-A/ MSLO-Ⅳ
X-ray Tube Assembly                         H1080
Collimator                                            M-38
Digital Detector                                   1717SCC
DR Machine Frame                            MSLDR-Ⅰ
Radiography Table                             MSLS-Ⅲ
Computer and LCD                            DCSM1F
Synchronous box                                 MSLT-Ⅰ
High Voltage Cable                             75kV (length: 8m)
 
 
High Frequency High Voltage X-ray Generator MSLG50R-A
MSLG50R-A/ MSLO-Ⅳ              operating console
Power                                           AC380V ± 38V
Radiography Tube Voltage       40kV ~ 150kV
Radiography Tube Current       10mA ~ 630mA
Time                                               2ms ~ 6300ms
Allowed Internal Resistance     380V: 0.5Ω
Allowed Frequency Variation     50Hz/60Hz ± 1Hz
Working Frequency                      ≥30kHz
 
 
X-ray Tube Assembly H1080
Focus                          0.6mm/1.2mm
Rotating Speed         3000rpm
Peek Tube Voltage   150kV
Small Focus               20kW
Large Focus               50kW
 
 
Collimator M-38
Mode of adjustment Manual
Power                              24VAC
Inherent Filtration         1.2mmAL
 
 
Digital Detector1717SCC
Scanning Area                                   17 × 17 inches
Spatial Resolution                             not less than 3.6lp/mm
Total Pixel Matrix                                 3328(h) × 3328(v)
Pixel Pitch                                             ≤127μm
A/D                                                         16Bit
Detector Imaging Time                      not more than 4S
 
 
DR Machine Frame MSLDR-Ⅰ
Up and Down Moving Range of UC arm with the Column            700mm ~ 1700mm
Rotating Range of UC arm along with the Column                        0°~ 105°
Up and Down Moving Range of Detector                                          700mm ~ 1700mm
Moving Range of X-ray Tube Assembly                                             0 ~ 800mm±50mm
SID                                                                                                            1000mm ~ 1800mm
 
 
Radiography Table MSLS-Ⅲ
Tabletop Size (Length × Width × Height)       2020mm × 690mm × 680mm
Mode of Operation                                              Manual
Load-bearing                                                       Less than 200kg
 
 
Computer and LCD DCSM
CPU                        ≥2.8GHz
Memory                   ≥4GB 
Disk Capacity         ≥500GB
Medical LCD          ≥19"