| Rated Current: | 270A |
|---|---|
| Rated Voltage: | 220/380V |
| Rated Power: | 150KW |
| Frequency: | 50HZ |
| Speed: | 1500RPM |
| Output Type: | AC Three Phase |
| Model Number: | JGC150GF |
| Brand Name: | FD |
| Place of Origin: | China (Mainland) |
| Engine Model: | 6CTAA8.3-G2 |
| Configuration: | 4 cycle , 6 cylinders in line |
| Aspiration: | Turbocharged after water-cooled |
| Bore*Stroke: | 114 *135 mm |
| Displacement: | 8.3L |
| Compression Ratio: | 16.5:1 |
| Prime Power: | 163KW |
| Speed Governor: | electrical |
| Alternator Model: | UCI274H |
| Exciter type: | Brushless, Self-excited |
Quick Details
Specifications
150KW Cummins Diesel Genset for Sale
Genset Main Technical Data
|
Generator Model |
JGC150GF |
|
Prime power |
150KW |
|
Standby power |
163KW |
|
Voltage |
415V |
|
Frequency |
50HZ/1500 rpm |
|
Power factor |
0.8(lag) |
|
Governor type |
Electric |
Prime Power : Prime power is available for an unlimited number of annual hours in variable load application, in accordance with GB/T2820-97; A 10% overload capability is available for a period of 1 hour within a 12-hour period of operation.
Standby Power Rating : The standby power rating is applicable for supplying emergency power for the duration of a utility power interruption. No overload, utility parallel or negotiated outage operation capability is available at this rating.
Reliable Performance
Voltage regulation
Voltage regulation maintained within ±0.5% as follow:
● Power factor Between 0.8~1.0 lag
● From no load to full load, any steady load
● Speed droop variation under 4.5%
Frequency/Speed undulation
● Change load from 0-100%, Frequency/Speed Droop Ratio within 5%
● Load from 25-100%, any steady load Frequency/Speed undulation within 0.25%
Effect factor of telecom
● Telephone Influence Factor (TIF) : Less than 50
THF : Less than 2%
● ISO8528, GB/T2820
● EN12601:2001, EN60034-22:1997, EN60204-1:2006
● ISO9001:2008 Quality Control System
Open Type
Overall size (L*W*H)
2350*850*1300
Weight: 1450kg
Technical Data
|
Engine Model |
6CTAA8.3-G2 |
|
Configuration |
4 cycle , 6 cylinders in line |
|
Aspiration |
Turbocharged after water-cooled |
|
Bore×Stroke |
114 x135 mm |
|
Rated speed |
1500rpm |
|
Displacement |
8.3L |
|
Compression Ratio |
16.5:1 |
|
Prime Power |
163KW |
|
Speed Governor |
electrical |
|
Cooling System |
Water-cooled , 40℃Radiator As Standard, 50℃Is Optional. |
|
Speed Stability (%) |
≤5% |
|
Fuel Consumption at 100% Load |
210g/kw.h |
|
Starter Motor |
DC24V, |
Alternator SPECIFICATION
|
Brand |
Stanford |
|
Alternator Model |
UCI274H |
|
Capacity |
160KW |
|
Voltage |
415V |
|
Frequency & Speed |
50HZ/1500RPM |
|
Exciter type |
Brushless, Self-excited |
|
Power factor |
0.8 |
|
Voltage Adjust range |
≥5% |
|
Voltage Regulation NL-FL |
≤±0.5% |
|
Insulation Grade |
H |
|
Protection Grade |
IP23 |
Control System
Deep Sea 8110
Details please see the attach document
KEY FEATURES
Configurable inputs (11)
Configurable outputs (8)
Built-in governor and AVR control
Comprehensive electrical protection
Comprehensive loadshare capabilities
RS232, RS485 & Ethernet remote communications
Modbus RTU/TCP support
Back-lit LCD graphical display
Configurable display languages
Audible alarm
Reduced file transfer time
Engine protection
Fault condition notification to a designated PC
Compatible with DSE8700 & DSE8600 Series
Front panel editing with PIN protection
Flexible sender inputs
Configurable timers and alarms
3 configurable maintenance alarms
Multiple date and time scheduler
Configurable event log (250)
Easy access diagnostic page
CAN and Magnetic Pick-up/Alt. sensing
Fuel usage monitor and low fuel alarms
Manual fuel pump control
" Protections disabled" feature kW overload protection
Reverse power protection
Power monitoring (kW h, kV Ar, kV A h, kV Ar h)
Load switching (load shedding and dummy load outputs)
Unbalanced load protection
Independent Earth Fault trip
USB connectivity s
Backed up real time clock
Fully configurable via DSE
Configuration Suite PC software
Advanced SMS messaging
(additional external modem required)
Start & stop capability via SMS messaging
Additional display screens to help with modem diagnostics