| Rated Current: | 288A |
|---|---|
| Rated Voltage: | 380V |
| Rated Power: | 160KW |
| Frequency: | 50HZ |
| Speed: | 1500RPM |
| Output Type: | AC Three Phase |
| Model Number: | JGP160GF |
| Brand Name: | FD |
| Place of Origin: | China (Mainland) |
| Engine Model: | 1306C-E87TAG3 |
| Configuration: | 4 cycle , 6 cylinders in line |
| Aspiration: | Turbocharged air to air cooled |
| Bore*Stroke: | 116.6*135.9 mm |
| Displacement: | 8.7 L |
| Prime Power: | 180KW |
| Speed Governor: | Electronic |
| Cooling System: | water-cooled |
| Alternator Model: | UCI274H |
| Exciter type: | Brushless, Self-excited |
Quick Details
Specifications
160KW Perkins Diesel Genset for Sale
General feature
Coupled with Perkins diesel engine and Stamford Or Marathon alternator 24V DC start motor and storage battery
Brushless, Self-excited, IP23, insulation class H alternator
40℃ radiator as standard, 50℃ is optional
Key start panel control system as standard, digital auto-start panel is optional
Optional open type or silent type
All generator sets are gone through rigorous testing before being released to the market place, including 50% load, 75% load, 100% load , 110% load and all protection function (overspeed stop, high water temperature, low oil pressure, battery charging fail, emergency stop)
Genset Main Technical Data
|
Generator Model |
JGP160GF |
|
Prime power |
160KW |
|
Standby power |
176KW |
|
Voltage |
380V/220V |
|
Frequency |
50HZ/1500 rpm |
|
Power factor |
0.8(lag) |
|
Governor type |
Electronic |
Prime Power : Prime power is available for an unlimited number of annual hours in variable load application, in accordance with GB/T2820-97; A 10% overload capability is available for a period of 1 hour within a 12-hour period of operation.
Standby Power Rating : The standby power rating is applicable for supplying emergency power for the duration of a utility power interruption. No overload, utility parallel or negotiated outage operation capability is available at this rating.
Reliable Performance
Voltage regulation
Voltage regulation maintained within ±0.5% as follow:
●Power factor Between 0.8~1.0 lag
●From no load to full load, any steady load
●Speed droop variation under 4.5%
Frequency/Speed undulation
●Change load from 0-100%, Frequency/Speed Droop Ratio within 5%
●Load from 25-100%, any steady load Frequency/Speed undulation within 0.25%
Effect factor of telecom
●Telephone Influence Factor (TIF) : Less than 50
THF : Less than 2%
Certificate
●ISO8528, GB/T2820
●EN12601:2001, EN60034-22:1997, EN60204-1:2006
●ISO9001:2008 Quality Control System
Open Type
Overall size (L*W*H)
2500*1000*1650
Weight: 1600kg
ENGINE SPECIFICATION
Perkins Diesel Engine
Technical Data
|
Engine Model |
1306C-E87TAG3 |
|
Configuration |
4 cycle , 6 cylinders in line |
|
Aspiration |
Turbocharged air to air cooled |
|
Bore×Stroke |
116.6x135.9 mm |
|
Rated speed |
1500rpm |
|
Displacement |
8.7 L |
|
Compression ratio |
16.9:1 |
|
Prime Power |
180KW |
|
Speed Governor |
Electronic |
|
Cooling System |
water-cooled |
|
Speed Stability (%) |
≤5% |
|
Fuel consumption |
207 g/kw.h |
|
Starter Motor |
24V |
Alternator SPECIFICATION
Technical Data
|
Brand |
Stamford |
|
Alternator Model |
UCI274H |
|
Capacity |
160KW |
|
Voltage |
220/380V |
|
Frequency & Speed |
50HZ/1500RPM |
|
Exciter type |
Brushless, Self-excited |
|
Power factor |
0.8 |
|
Voltage Adjust range |
≥5% |
|
Voltage Regulation NL-FL |
≤±0.5% |
|
Insulation Grade |
H |
|
Protection Grade |
IP23 |
Control System
1. Standard: HGM180HC Key Start
Providing the standard functions as follows:
(Also can be made according to the customers' special requirements)
*Start/Stop controller
*Ampere meter
*Voltmeter and selector switch
*Frequency meter/ Water temperature gauge/ Oil pressure gauge/ Hour counter/ Battery voltage meter
*Emergency stop pushbutton
*Alarm System: Over speed, High Engine Temperature
Low Oil Pressure, Charge Fail
*Protection System: Over speed, High Engine Temperature, Low Oil Pressure, Emergency Stop. And the other protection function pre-setting
2. Option: Smartgen HGM6110 Digital Auto Start
3. Option: Smartgen HGM6120 Digital Auto Start
(Option assembled with the ATS)
4. Option: Deep Sea DSE5210 Digital Auto Start
5. Option: Deep Sea DSE5220 Digital Auto Start
(Option assembled with the ATS)
Digital Auto-start Generator controller integrating digital, intelligent and network techniques is used for automatic control system of diesel generator. It can carry out functions including automatic start/stop, data measure and alarming. Optionally assembled with the ATS, it can carry out auto-switching between the outer power and generating set power. (AMF)
Functions:
*Automatic Start/Stop
*3 start attempts failure and Automatic Crank Disconnect
*Parameters display (V/A/Hz/Hour)
*Engine monitoring and protection
*Charge alternator exciting and Charge alternator fail alarm
*Running hour counting
*Settings can be adjustable via key buttons on front panel