Product Main

Quick Details

Rated Current: 180A
Rated Voltage: 400V
Rated Power: 100KW
Frequency: 50HZ
Speed: 1500RPM
Output Type: AC Three Phase
Model Number: JGC100GF
Brand Name: FD
Place of Origin: China (Mainland)
Engine Model: 6BTA5.9-G2
Aspiration: Turbocharged after water-cooled
Bore*Stroke: 102 *120 mm
Speed Governor: electrical
Alternator Model: MP-104-4
Exciter type: Brushless, Self-excited

Specifications

100KW Trailer Diesel Generator

STANDARD SPECIFICATION

●   Coupled with Cummins diesel engine and Stamford

    Or Marathon alternator

●   24V DC start motor and storage battery

●   Brushless, Self-excited, IP23, insulation class H alternator

●   40℃ radiator as standard, 50℃ is optional

●   Key start panel control system as standard, digital auto-start panel is optional

●   Optional open type or silent type

●   All generator sets are gone through rigorous testing before being released to the market place, including 50% load, 75% load, 100% load , 110% load and all protection function (overspeed stop, high water temperature, low oil pressure, battery charging fail, emergency stop)


General feature

Genset Main Technical Data

Generator Model

JGC100GF

Output power

100KW

Voltage

380V/220V

Frequency

50HZ/1500 rpm

Power factor

0.8(lag)

Governor type

Electric

Reliable Performance

Voltage regulation

Voltage regulation maintained within ±0.5% as follow:

● Power factor Between 0.8~1.0 lag

● From no load to full load, any steady load

● Speed droop variation under 4.5%

 Frequency/Speed undulation

● Change load from 0-100%, Frequency/Speed Droop Ratio within 5%

● Load from 25-100%, any steady load Frequency/Speed undulation within 0.25%

Effect factor of telecom

● Telephone Influence Factor (TIF) : Less than 50

                           THF : Less than 2%

Certificate

● ISO8528, GB/T2820

● EN12601:2001, EN60034-22:1997, EN60204-1:2006

● ISO9001:2008 Quality Control System
Dimension and Weight

Open Type

Overall size (L*W*H)

2150*750*1200

Weight: 1050kg

ENGINE SPECIFICATION

Cummins Diesel Engine

Technical Data

Engine Model

6BTA5.9-G2

Configuration

4 cycle , 6 cylinders in line

Aspiration

Turbocharged after water-cooled

Bore×Stroke

102 x120 mm

Rated speed

1500rpm

Displacement

5.9 L

Compression Ratio

17.5:1

Prime Power

100KW

Speed Governor

electrical

Cooling System

Water-cooled , 40 Radiator As Standard, 50 Is Optional.

Speed Stability (%)

≤5%

Fuel Consumption at 100% Load

211g/kw.h

Starter Motor

DC24V,

Alternator Specification

Technical Data

Brand

MARATHON

Alternator Model

MP-104-4

Capacity

104KW

Voltage

220/380V

Frequency & Speed

50HZ/1500RPM

Exciter type

Brushless, Self-excited

Power factor

0.8

Voltage Adjust range

≥5%

Voltage Regulation NL-FL

≤±0.5%

Insulation Grade

H

Protection Grade

IP23

 Control System

1. Standard: HGM180HC Key Start

Providing the standard functions as follows:

(Also can be made according to the customers' special requirements)

*Start/Stop controller

*Ampere meter

*Voltmeter and selector switch

*Frequency meter/ Water temperature gauge/ Oil pressure gauge/ Hour counter/ Battery voltage meter

*Emergency stop pushbutton

*Alarm System: Over speed, High Engine Temperature

Low Oil Pressure, Charge Fail

*Protection System: Over speed, High Engine Temperature, Low Oil Pressure, Emergency Stop. And the other protection function pre-setting

2. Option: Smartgen HGM6110 Digital Auto Start

3. Option: Smartgen HGM6120 Digital Auto Start

   (Option assembled with the ATS)

4. Option: Deep Sea DSE5210 Digital Auto Start       

5. Option: Deep Sea DSE5220 Digital Auto Start

   (Option assembled with the ATS) 

Digital Auto-start Generator controller integrating digital, intelligent and network techniques is used for automatic control system of diesel generator. It can carry out functions including automatic start/stop, data measure and alarming. Optionally assembled with the ATS, it can carry out auto-switching between the outer power and generating setpower. (AMF)

Functions:

*Automatic Start/Stop

*3 start attempts failure and Automatic Crank Disconnect               

*Parameters display (V/A/Hz/Hour)

*Engine monitoring and protection

*Charge alternator exciting and Charge alternator fail alarm

*Running hour countin

*Settings can be adjustable via key buttons on front panel