Usage: | NDT |
---|---|
Power: | Electronic |
Model Number: | XXGH-2505 |
Brand Name: | DDYG |
Place of Origin: | China (Mainland) |
Max output: | 250KVa |
Max penetration: | 37mm |
Quick Details
Specifications
Features:
1. An thorough self-diagnosis for software and hardware at start-up stage can effectively detect component error.
2. Strong anti-interference properties enable X-ray Equipment to be powered by electric generator.
3. Easily set exposure parameters on panel.
4. Delay before exposure to spare time for evacuation.
5. Gradually increase and decrease voltage to protect x ray tube and high-voltage coil.
6. 1:1 duty cycle
7. Protection against over-kV, over-mA, under-kV, under-mA, over-temperature.
8. this x-ray machine is of portable structure, and convenient for operating outdoor.
9. High voltage coil is made from insulating &temperature-resistant materials
10. Small size, light weight, and easy operation
11. Chamber of X-ray generator is filled with SF6 gas for insulation, ground anode, and cool with fan.
12. Warning light fitted
Specifications
Items |
Parameters | |
Model |
XXGH-2505 | |
Max. Penetration(A3 Steel) |
37 mm | |
Focal Length |
600 mm | |
Exposure Time |
5 minutes | |
Film Type |
T3 | |
Operation Temperature in Darkroom |
20±2℃ | |
Developing Time |
5 minutes | |
Blackening |
≥1.5 | |
Sensitivity |
≤1.8% | |
Input |
Voltage |
AC198-240V/50Hz (60Hz) |
Capacity |
3.5kVA | |
Ambient Temperature |
-30℃~40℃ | |
Ambient Humidity |
≤85% | |
X-ray Tube | ||
Tube material |
Ceramic | |
Emission |
Panoramic | |
Focal Size |
1.0×2.5mm | |
Radiation Angle |
360 o*25° | |
Output Voltage |
160-250kV (±2%) | |
Output Current |
5mA (±2%) | |
X-ray Generator | ||
Cooling |
Fan | |
Insulation |
SF6 | |
Pressure Gauge |
0.34MPa~0.45MPa | |
Dimension |
D270*H615mm | |
Weight |
32Kg | |
Controller | ||
Dimension |
350×290×150mm | |
Weight |
10Kg |