Application:
Measuring the volume of cold potable water passing through the pipeline with remote reading device
Features:
Dry type. Small, light, magnetic drive, free rotating register, easy and long term clear reading etc. Magnet resistance. Length of body of 80mm or 110mm is available.
Data Output Options:
10 L/Pulse, 100 L/Pulse, or 1000 L/Pulse
Reed Switch Electric Data
Voltage: 24V AC/DC max.
Current: 0.01A max
Working Condition:
Water temperature:
≤40ºC for cold potable water meter
≤90ºC for cold potable water meter
Pressure: ≤1Mpa
Maximum Permissible Error
A) In the lower zone from Qmin inclusive up to but excluding Qt is: Cold potable and Hot water meter±5%
B) In the upper zone from Qt inclusive up to and including Qs is: Cold potable water meter±2% Hot water meter±2%