Product Main

Specifications

 
Single Phase Energy Meter Test Instrument (Split Type)
Overview:
The RT6103-S Single Phase Energy Meter Test Instrument (Split Type) adopts internationally advanced new-generation digital power source technologt,integrates all the technological advantages of both domestic and foreign watt-hour meter calibration software, and is introduced to global market by Rowwin Test in a powerful and sensational way.The single phase energy meter test instrument comprises of PWM power source,standard digital energy meter,error processor and PC processing software,this energy meter test instrument can test 3 to 60 various watt-hour meters of Grade 0.5 or lower simultaneously,also is an ideal new-generation multi-position energy meter testing instrument.
Technical Parameters:   
1.    Accuracy class: 0.1/0.05
2.    Reference standard energy meter: Single phase wide-measurement range standard energy meter.(Accuracy class:0.1/0.05)
     Multi-path voltage transformer: Accuracy class:0.01; Rated load per path:10VA
3.    Voltage range:220v(240V option),Output range:0~125%,Resolution:0.01%full range
4.    Current measurement range:0.1~100A(200A option),Output range:0~120%,Resolution:0.0001A(minimum)
5.    Phase angle:0~360°,Resolution of phase angle setting:0.01°
6.    Frequency:45Hz~65Hz,Resolution:0.01Hz
7.    Output waveform distortion:Both voltage and current<0.5%
8.    Output voltage,current and power stability:<0.05%
9.    Output capacity:Current:1,000VA(120A);Voltage:400VA(24 meter testing positions)
     If necessary,the maximum load can be extended to Current:1,800VA  and Voltage:1,000VA
10.  Load characteristics:Resistive,inductive and capacitive(less than 4uF)
11.  Starting current output:5mA(minimum);Accuracy:5%;Starting power:Accuracy 5%
12.  Energy meter testing positions:24/48 standard (3 ~60 meter positions also available)
13.  Testing functions:Accuracy testing,Creep testing(no load testing),Starting up testing,Harmonic testing,Repeatability testing,
      Influencing testing,Dial testing and etc
14.  Input power supply:220VAC,±10%,50Hz;Max.power consumption:1,500VA(24 meter testing positions)
 
Dimension:
24 meter testing positions(1 rack): 2200*700*1920mm
48 meter testing positions(2 racks): 2200*700*1920mm each
Cabinet: 600*800*1600mm