Adjustment of accurary
The adjustor is fixed on the adjusting cover of cylinder cover I.The oil discharge volume reduces if adjusting clockwise,and it increases if adjusting anti-clockwise.Total adjusting volume is 240ml and min.adjusting increment is 0.05%.The adjustor is set at"zero position"and sealed with lead at factory.
■ General introduction
This product can be used together with oiling machine to measure fuel with pressure source.It has such advantages as reasonable design,compact structure and accurate measurement.
■ Material
Body:aluminum(surface spray paint)
Sealing:NBR
■Technical Parameters
Discharge rate:0.5L per revolution
Diameter of output axis:9mm
Rotary direction of output axis:Clockwise
Overall dimensions:
Level:200?00mm
Horizontal:200mm
Vertical:200mm
Diameter of cylinder cover:72.4mm
Travel of crankshaft:14.93mm
Travel of piston(2and4):29.80-31.38mm
Adjusting range of piton quantity(1and3):29.86mm
Min.adjusting increment:0.05%
Working pressure:0.12mPa-0.3mPa
Accuracy:?.2%(within 5L/min to 100L/min)
Repeat error:not exceed?.1%
No leakage under 0.3MPa air pressure.