Product Main

Specifications

1.       Effective oven length: 60m; 4temperature zones, each zone can be adjusted individually.

2.       Heat insulation: two sides: 200mmtop: 250mmbottom: 100mmmaterial: glass wool

3.       Maximum heating capacity: 450000kcal/h

4.       Main power3 phase, 380V, 5.5kw

5.       Baking time5min40mintime displaydigital

6.       Automatic temperature adjustment and control. Gas is controlled by electromagnetic valve and air pressure valve.  proportion  valve and thermal detecting stick: 8pcs; gas emergency shutter: 1pcair blower: 4units

7.       Oven is divided into four temperature zonesTemperature of each zone can reach around 350. The temperature of each side is balanced well to bake the product evenly. Each zone has smoke exhaust and dehumidify exit (with motor) and controlled separately. With 4 lighting and observing windows.

8.       Gas safety device.

a. blower will exhaust 5 times air and remained gas of oven before ignitingA detector is mounted to detect the working condition of the blower.

b. Gas pressure abnormity inspecting device; high gas pressure and low gas pressure inspecting, alarming and automatic stopping system.

c. Low air pressure inspecting and automatic stopping system.

d. Device to check whether the blower is closed before igniting.

9.       Manual steel band cooling device. In case the steel band abnormally stop due to power supply failure or other cause, the steel band can be driven manually to prevent the deform of steel band under high temperature.

10.   When steel band running deviation ≥5mm, it will be foreseen, alarmed and automatically adjusted to normal track detected by position switch);equipped with buzzer alarm light.

11.   Appearance: off-white baking paint, movable insulation board; 

13. Equipped with steel band cleaning device (steel wire brush), and   1 unit up scraper and 1 unit down scraper.

14. Automatic steel band protection system to ensure the steel band will be only stopped when its temperature and the temperature inside the chamber is detected below 100.

15. Failure automatic detecting and displaying system

16. Maximum capacity: 1500kg/h

17. The installed position of thermal detecting stick is very important: the detected temperature shall be consistent with the displayed temperature.