Single point type:one host machine and one output unit
Double poiv type:two host machines and two output units
Distance setting of detection operation:(a)position0.8mm to 1.2mm. After
pressing the set switch,you will see199to0,and then move the iron block of
the detector head to adjust the operation distance from80to 120(i.e.0.8mm
to 1.2mm).After the setting is completed,press the set switch to reset.
Setting of monitor's value,the precision setting range is1m±~99±m,and the
monitored value will beset upon request.
When the punch tool starts,the first four displayed mumbers of this detection
are the average value of the fool height(this value will only bere-calculated
when the press power is turned off or the sensing line is away from the the
sensor andre-put into the sensor).
Op:appear when the sensing line and sensing head is broken or the sensing
ispulled out.
HL:the too high abnormal red lamp and high yellow lamp will be on(distance
exceeds more than 1.2mm)
LO:the too low abnormal red lamp and low yellow lamp will be on (distance
exceeds more than0.8mm).
ES:appear when there is such abnormal situation as error sending detection,
material used up detection and material squeezing detection.
When the work difference value display exceeds the set value,the abnormal
lamp will be on.
The machine has self-detection function.
The specification set value of this machine is in lum unit,which is optional
upon the need of tool accuracy.
Such detection can be addedd with error sending detection,material
used up detection(electronic eye detection)and material squeezing detection
(sensor rod detection).