Brand Name: | Cubic |
---|---|
Weight: | ... |
Sampling Method: | ... |
Size: | ... |
Alarm type: | ... |
Place of Origin: | China (Mainland) |
Quick Details
Specifications
Introduction
Gasboard 3000Plus is designed with world-leading micro-flow infrared sensor, is able to measure continuously simultaneously concentration of CO,CO2,SO2,NO,especially for lower range measurement. It is an ideal solution for monitoring in fields of boiler, power plant, combustion efficiency monitoring for various industrial furnaces or refuse incinerator, process and security monitoring.
Features
1.PCT approved product based on micro-flow NDIR technology to measure low concentration gases. (US Authorization No.:US11079322).
2.Adopting micro-flow NDIR gas sensor technology, higher precision and longer life time.
3.Monitoring the lower range of SO2, NO, CO,CO2 within 200ppm.
4.No cross interference between measurement gases.
5.Diagnostic function can check sensor status.
6.Sampling flow rate fluctuations have no effect on the measurement results.
7.Accurate measurement of low concentration gas.
8.Built-in pump to achieve automatic zeroing.
9.Real-time continuous monitoring concentration of SO2, NO, CO, CO2, O2, measurement component is optional.
10.LCD (320*240) display.
11.Digital and analog signal output.
Gasboard 3000Plus is designed with world-leading micro-flow infrared sensor, is able to measure continuously simultaneously concentration of CO,CO2,SO2,NO,especially for lower range measurement. It is an ideal solution for monitoring in fields of boiler, power plant, combustion efficiency monitoring for various industrial furnaces or refuse incinerator, process and security monitoring.
Features
1.PCT approved product based on micro-flow NDIR technology to measure low concentration gases. (US Authorization No.:US11079322).
2.Adopting micro-flow NDIR gas sensor technology, higher precision and longer life time.
3.Monitoring the lower range of SO2, NO, CO,CO2 within 200ppm.
4.No cross interference between measurement gases.
5.Diagnostic function can check sensor status.
6.Sampling flow rate fluctuations have no effect on the measurement results.
7.Accurate measurement of low concentration gas.
8.Built-in pump to achieve automatic zeroing.
9.Real-time continuous monitoring concentration of SO2, NO, CO, CO2, O2, measurement component is optional.
10.LCD (320*240) display.
11.Digital and analog signal output.
Measurement Components |
SO2, NO, CO, CO2, O2 |
Measurement Technology |
SO2/NO/CO: Micro-flow NDIR; CO2: NDIR; O2: ECD |
Measurement Range |
SO2/NO: (0-200)ppm; CO: (500-5000)ppm; CO2/O2: (025)% |
Accuracy |
≤±2%F.S. |
Resolution |
SO2/NO: 1ppm; CO: 1ppm; CO2/O2: 0.01% |
Repeatability |
2% |
Response time |
T9025s(NDIR) |
Flow rate |
(0.7~1.2)L/min |
Output |
RS-485/RS-232, (4-20)mA |
Power Supply |
100~240VAC, 150W |