Introduction to the protection of energy-saving air-conditioning Energy-saving + protection, peace of mind to save money + The protection of energy-saving air-conditioning is the use of micro-power microcontroller, such as high-tech and digital integrated circuits made of modern design, easy to use, can extend the life of air-conditioning, power-saving efficiency of 30 percent and has launched a call to protect Delay And over-voltage, under-voltage protection, can be widely used in the family, shopping centres, factories and other air-conditioned places. First, energy-saving principles The Power Saver is by optimizing the operation of the compressor, refrigeration equipment make full use of the remaining cold to improve the efficiency of refrigeration. Mainly in the following areas: 1. Energy conservation minimum temperature: From the operation of the compressor curve indicates that the compressor operation near the minimum temperature with two temperature increases, the current increase of consumption of energy increased, while cooling the temperature dropped very little or no decline, when the Power Saver control its output signal Stands, this part of energy conservation, so that all the compressor cooling system. 2. Cessation of operation of the compressor, air-conditioning system is also available in surplus, then, the indoor fans have been at work, blowing out the air-conditioning or when the remaining air-conditioning system used, the output signal to the Power Saver control compressor Start work, so cycle, to energy-saving role. 3. Compressor to avoid frequent starter Compressor start and stop relying on the temperature control, temperature higher than the target stopped, the temperature below the target set, the actual observation is a return in a few minutes, a frequent launch, we have a big impact on current, and power consumption, Power Saver cycle is the work of a few dozen minutes a round-trip and avoid the large current compressor caused by the frequent shocks, to extend the life of the compressor. Second, product features The energy-saving protection, through the optimization of the compressor running time and make full use of refrigeration equipment in the remaining cold to improve the efficiency of refrigeration. Mainly in the following areas: 1. Energy-saving: by adjusting power-saving time and run time to control air-conditioning energy-saving downtime and run-time. According to the temperature in as short as possible running time, to achieve energy-saving purposes. 2. Delay Protection: The delay on the way to protect the compressor, the compressor to reduce the impact. 3. Overvoltage, under-voltage protection. Third, energy-saving air-conditioning for the protection of technical parameters Model: KTJD-518 voltage: AC180 ~ 240V rated frequency: 50 HZ Load Control power: 1.5 P the following models: 2000 W resistive load below the maximum current 10 A, inductive load below 600 W, the maximum current 6 A. 1.5P above models: 8000 W resistive load below the maximum current 40 A, inductive load below 4000 W, the maximum current 20 A. Appearance size: 170 × 90 × 40mm work: for Quick Start time: <1 second Energy-saving rate: 25% -50%, continuous-tuning. Use of the environment: -20 - +40 local power: 5 W