Product Main

Specifications

Product feature
Wide range of AC input voltage: 90V AC-264V AC
Protections against : short circult/over current/over voltage
Meets standard 2MOPP of medical devices
Meets requirement of energy efficiency level VI Tier2 of CoC V5
Meets 4kV surge immunity IEC/EN61000-4-5
With interchangeable AC plugs, worldwide application
No Y-capacitor design
Technical data
Input voltage: 90-264V AC 
Input current: 200mA
Output voltage range: ±5%
Standby power: 0.075W
Average Efficiency: meets Energy Star Level VI
Reliability
At 25°C ambient temperature, maximum load work 50,000 hours MTBF (according to MIL - HDBK - 217 standard)
Machinery specification
Interchangeable AC plugs: 73.5mm (L), 42.5mm (W, 30.7mm (H)
Interchangeable AC plugs: 72.0mm (L), 42.4mm (W), 26.1mm (H)
Fixed AC plugs: 72.0mm (L), 42.4mm (W), 26.1 mm (H)
Environmental requirement
Operating temperature: 0°C-40°C
Storage temperature: -20°C-60°C
Humidity enrichment conditions, humidity: 5%-95%
Safety standard
Medical: IEC/EN60601 UL/CUL60601
ITE: IEC/EN60950 UL/CUL60950 J60950 AS/NZS60950
Applications
Medical devices, ITE devices
Output data
Model voltage
(V) current
(A) ripple