Forward Gain10dB, Reverse passive | |||||
|
Parameter |
|
Typical |
Worst |
Unit | |
|
Forward Path 54-1000 MHz | |||||
|
Gain |
10 |
9 |
| ||
|
Flatness |
|
± 0.7 |
± 1 | ||
|
Hum Modulation |
|
-80 |
-75 |
dBc | |
|
Cross Modulation |
|
-75 |
-70 | ||
|
CTB |
|
-75 |
-70 | ||
|
CSO |
|
-65 |
-62 | ||
|
Noise Figure |
|
2.5 |
4 |
dB | |
|
Group Delay |
CH2 |
Span 3.58MHZ |
20 |
ns | |
|
CH3 |
10 | ||||
|
CH5 > |
5 | ||||
|
Return Path 5-42 MHz | |||||
|
Insertion Loss |
-0.5 |
-1 |
dB | ||
|
Flatness |
|
± 0.3 |
± 0.5 | ||
|
Group Delay |
5-42 MHZ |
Span 1MHZ |
20 |
ns | |
|
10-36 MHz |
3 | ||||
|
General Specifications 5-42 MHz, 54-1000 MHz | |||||
|
Impedance |
|
75 |
Ohm | ||
|
Return Loss |
|
20 |
18 |
dB | |
|
RFI |
|
100 | |||
|
Surge Withstand Capability |
6kV 3kA,Combo Wave IEEE (C62.41-1991) Category B3 Standard | ||||
|
6kV 200A,Ring Wave IEEE (C62.41-1991) Category A3 Standard | |||||
|
Operating Temperature |
|
-40 to +60 |
o C | ||
|
Power Consumption |
DC12V |
120 mA | |||
|
Waterproof |
All F Ports |
Withstand 15 lbs/inch for 1 minute |
| ||
|
Note: |
|
|
|
| |
|
(1) Input levels at +13.5 dBmV/CH (79 NTSC), plus digital after 550MHz at 6dB set-back. | |||||