| Features: |
◆ Can measure a variety of devices from low-speed modems to high-speed digital lines The CE5009 can be configured to a variety of communications protocols via CCITT by using each interface.It can perform high-quality evaluations of data communications systems that have bit rates from 50 bit/s to 2048kbit/s. ◆ Simultaneous error measurement of various error parameter The error count(bit error,frame error,and CRC error,etc.),error rate,block error count,block error rate,US,%US,SES,%SES, DM,% DM ES,%ES,EFS,%EFS,clock slip,and synchronization loss can be measured.Alarm states such as AIS can be continuous monitored. ◆ Error added The CE5009 can add errors singling or at a fixed rate according 10-N during testing. ◆ G..821 and G..826 analysis All G..821 and G.826 parameters are measured by the CE5009.The G..821 parameter thresholds are programmable to allow performance analysis to the user's own performance targets. ◆ Histogram result analysis The CE5009 provides time analysis of bit errors and up to 14 alarm and error events using histograms. ◆ Test record management The CE5009 can storge,view,print and delete the selected record.Or tranfer the selected record to the computer.Or clean all records. ◆ Power supplied The power of the CE5009 can be supplied by DC9V external or built-in chargeable batteries.The CE5009 can be used continuously for four hours when the batteries is charge filled. ◆ Pattern Pseudorandom Pattern:26-1,29-1,211-1,215-1,220-1,223-1 Fixed Pattern:ALL1,ALL0,1010,1100,1000,1110 Word 16 Pattern ◆ Record hold time Results recorded on the memory can be used for comparison in yearly and calibration or after repairs or adjustment. ◆ Real-time clock The CE5009 provides a electric clock built-in.You can adjust the clock real-time.The electric clock is running while the power is failure.
|
| |
| Main Specifications: |
◆ Specifications of Data Interface Terminal imitation:The CE5009 can emulate DTE and DCE. Synchronous Mode: Clock:Internal Clock,External Clock Rising Edge,Falling Edge Clock Rate:1.2,2.4,4.8,9.6,14.4,19.2,38.4,48,56(kb/s) N×64kb/s(N=1~32), Error limit:±15ppm Asynchronous Mode:Transmitting Rate:50,75,110,150,200,300,600,1200,2400, 3600,4800,7200,9600(b/s);14.4,19.2,38.4,57.6(kb/s) Data Format:Data length:5,6,7,8(bits) Stop bit:1,2(bits) Verification Code:Odd,Even,1,0,none Test Target:BE/BER,Block ERR/Block ER,G.821 Analysis Alarm:Sig Loss,ALL1,ALL0,Syn Loss,>10-3,BE/BER
◆ Specifications of G.703-2M Offline Clock rate:2048k±102(bit/s) Output:unbalanced 75Ω,HDB3(or AMI); Output voltage:±2.37V±10%; Input: unbalance 75Ω,HDB3(or AMI); Input voltage:±1.5 to ±3V; Test target:BE,BER,ES,EFS,SES,DM,ULS,AVS,etc; Alarm:Sig Loss,AIS,Syn Loss,>10-3,Bit Error.
◆ Specifications of G.703-2M Offline Clock rate:2048k±102(bit/s); Input impedance:Unbalanced high impedance(≥2kΩ) Digital line code:HDB3(or AMI). Test target:FAS Error,FAS Error rate,Code Errors,E-bit Error, Block Error,CRC4 Error,CRC4 Error rate, BE,BER,etc; G..821 Analysis: AVS, ES ,EFS,SES,DM,etc; G.826 Analysis: AVS, ES ,EFS,SES,Error Data Block,etc; Frame Analysis:Odd frame/0 Timeslot,Even frame/0 Timeslot,etc. Alarm:Sig Loss,AIS,Frame Sync Loss,>10-3,FAS Error, Multi-frame Loss,Remote Alarm Channel Monitor:Every 30 channels is selected arbitrarily.The volume is adjusted. Signaling Analysis:ABCD signaling analysis of 30 channels.(PCM30 System) Frame output:unbalanced 75Ω; Code:Framed HDB3(used for self-test).
| |