Product Main

Specifications

boiler model LHS0.2-1.0-Y(Q) WNS0.5-0.7-Y(Q) WNS1.0-0.7-Y(Q) WNS2-1.25-Y(Q) WNS4-1.25-Y(Q) WNS6-1.25-Y(Q) WNS8-1.25-Y(Q) WNS10-1.25-Y(Q) SZL20-1.25-Y(Q) SZL35-1.25-Y(Q)
nominal evaporation     kg/h            200 500 1000 2000 4000 6000 8000 10000 20000 35000
nominal working pressure     Mpa        1 0.7 0.7 1.25 1.25 1.25 1.25 1.25 1.25 1.25
nominal steam temperature           183.2 169 169 194 194 194 194 194 194 194
design efficiency                88 89 89 89 89 89 89 89 89 89
fuel consumption light oil kg/h                   14 37 72 150 285 425 535 668 1336 2338
heavy oil kg/h                     38 76 156 304 455 570 712 1424 2492
city gas Nm3/h                   31 88 170 357 675 1006 1266 1582 1364 5537
natural gasNm3/h                    44 85 178 338 503 633 791 1582 2769
main steam valve seat   mm             DN40 DN40 DN50 DN80 DN100 DN100 DN125 DN200 DN200 DN250
feed water tube diameter mm ZG1 DN25 DN25 DN25 DN40 DN50 DN50 DN50 DN65 DN80
blowdown tube diameter mm DN25 DN25 DN25 DN40 DN50 DN50 DN50 DN50 DN50 DN50
safety valve tube diametemmr    ZG11/2 1-DN40 1-DN40 2-DN40 2-DN50 2-DN80 2-DN80 2-DN80 2-DN100 2-DN150
chimney diameter    mm   150 300 350 350 500 600 700 800 1450 1880
max installed size length mm                   1380 2100 2800 3700 4000 4800 5500 6900 5700 6200
width mm                    1180 1200 1600 2000 2700 2800 3200 3500 3500 4000
height mm                    2180 1500 1900 2100 2600 2800 3800 4300 4700 5300
Central combustion three reheat backhaul oil(gas)-fired boiler
1. Because high temperature smoke and fire can be revolved strongly and back, the fuel can be burned out in low oxygen, so it is better be used in the plateau area.
2. High-temperature heating surface is below the central line of shell. Because there are a large scope of the water safety level. Boiler can be run safety.
3. Heating surface is reasonable, and the degree of automation is high. Compared with other boilers, it is small in the volume and area, also easier to be installed.
4. High efficiency. The fuel is fired suspended in big furnace, the back pressure of the boiler is small, the path of smoke is long.
5. it is good to the environment protection. Because there are 2 reheat cycle in the furnace, the fuel can be burned enough, also the smoke dust is little. This boiler is the production of green environment.
6. Reliable quality. Each KINGLLI boiler is inspected by Province Inspect Institute, then got the qualified certificate.
7. Because of automated control, KINGLLI boiler can be operated conveniently.
8. Maintain conveniently. It is easier to be fixed and maintained with swift open structure of front and back smoke box.

Boiler model:                  WNS3-1.25-Y(Q)
Nominal evaporation:           3tph
Nominal working pressure:      1.25Mpa
Nominal steam temperature:     194C
Design efficiency:             89%
Fuel consumption
Light oil:                     210kg/h
Heavy oil:                     223kg/h
City gas:                      496Nm3/h
Natural gas:                   248Nm3/h
Main steam valve seat:         DN80
Feed water tube diameter:      DN40
Blowdown tube diameter:        DN40
Safety valve tube diameter:    2-DN40
Chimney diameter:              450mm
Max installation size
Length:                        3900mm
Width:                         2000mm
Height:                        2100mm