Product Main

Specifications

613A Load Cell, 100kg…20,000kg/1,000 lb…20,000 lb 

(Interchangeable : Rice Lake:RL 30000, Revere: 5123, Sensortronics: 65023, Tedea-Huntleigh: 3411)

  

Special features:
●613A complies with OIML R60 C3 (Emax≥
    500kg) regulations up to 3 000d for scales 
    class III
● Low profile & high sensitivity
● Protection to IP67
● Explosion proof version (Ex ib II CT4)
● Available Options:
    - Service temperature range up to 120℃ [248℉]
    - Lightning proof
    - 6-wire circuit
    - Stainless Steel 613A  

 
Dimensions(in mm; 1mm = 0.03937 inches):

 

 

 

Technical Data
 

Type 613A

Accuracy class according to OIML R60
Maximal numbers of load cell verification intervals  (nLC) 

-
3000

C3
3000 / 5000

Maximal capacity (Emax)


Deflection at max. load, (Snom) approx. (±20%)
Weight (G), approx. 

kg/lb


mm
kg

100;
200;
300
0.45
1

500;1,000/
1,000;2,000;
2,500
0.45
1

2,000/
4,000; SE-5,000
0.6
1

3,000;5,000/
5,000;
10,000
0.8
1.8

10,000/
15,000;
20,000
1.1
4.1

20,000


1.4
5.5

Minimumload cell verification interval(Vmin)
Sensitivity (Cn)
Zero balance
Temperature effect on sensitivity (TKc) *
Temperature effect on zero balance (TKo)
Non-linearity (dlin)  *
Repeatability (drep)  *
Hysteresis error (dhy) *
Creep (dDR)in 30 min.
Input resistance (RLC) [Red(+)-black(-)]
Output resistance (RO) [Green(+)-white(-)]
Reference excitation voltage (Uref)
Maximal excitation voltage
nsulation resistance (Ris)
Nominal temperature range
Service temperature range
Storage temperature range

% of Cn
mV/V
mV/V
% of Cn/K
% of Cn/K
%
%
%
%
Ω
Ω
V(DC/AC)
V(DC/AC)

℃[oF]
℃[oF]
℃[oF]

0.03; 0.02
3±0.25%
±0.06
< ±0.0012
<±0.0040
<±0.017
<±0.017
<±0.017
< ±0.023
400 ± 25 for kg; 350 ± 7 for lb
352±3
0.5…12
18
>2[50 VDC ]
-10…+40[15…+105]
-30…+70[-20…+160]
-50…+85[-60…+185]

Safe load limit (EL)
Breaking load (Ed)

% of Cn
% of Cn

150
300

Protection class (IP) acc. to IEC529

 

IP67

Material

 

Alloy Steel / Stainless Steel (available)

Optionally

 

Explosion proof version (Ex ib II CT4)