Technical instruction
A: Temperature control segment:40 segment
The segment can be set in computer according to the actual requirement.
B: Temperature-zone numbers :Single-zone and multi-segment
C: Temperature control system:PC control system ,SSR non-contact output
D: Temperature accuracy : ± 2 ℃
E: Warm-up time:3min
F: Temperature range :Room-temperature -360 ℃
G: Heating supply :Infrared ray + Hot air convection
H: Effective working table area:360mm * 230mm (less than A4)
I: Welding time : 3min ± 1min
J Temperature curve: It can be set ,adjusted and tested according to the actual requirement .
K: Cooling system:Transverse flow equal cooling
N: Rated voltage:AC single-phase, 220V; 50Hz
O: Rated power :4.0KW Mean power: 1.8kw
P: Weight: 45 kg
Q: Dimension :Length*width*height 820′ 460 ′ 310mm