Product Main

Specifications

Application

-Used as power and control cable for protected installations inside and outside of rail and transport vehicles, where handling and installation cost are an important factor.

-Used in control, auxillary and main circuit wiring such as cable harnesses, switchboards and control panels, driver desks etc.

Construction

Conductor
Tinned annealed copper wires as defined in EN 50306-2

Insulation
LSZH special compound

Electrical & Mechanical Properties

Nominal Voltage 300/500 V
Maximum Conductor Temperature +120/+150 deg (fixed installation)
Minimum Permissible Ambient Temperature -25/-40 deg (fixed installation)
Bending Radius 3 x Overall Diameter

Chemical & Environmental Properties

EN 60684-2 No fluorine
EN 50305; EN 60811-2-1 Resistance to oil & fuel
EN 50305 Resistance to ozone

Fire Performance for rolling stock application

EN 50306-2 Hazard levels HL1, HL2/HL3, HL4
DIN 5510-2 Protection level 1/2/3/4
BS 6853 Interior use 1a, 1b, II; Exterior use 1a, 1b, II
NF F 16-101 FO

Fire Performance in general

EN 50265-2-1; IEC 60332-1; BS 4066-1 Vertical flame propogation for a single insulated wire or cable
EN 50266-2-4 + EN 50305; IEC 60332-3C; Fire propagation of bunched wires and cables;
VDE 0472 Teil 804; BS 4066-3; NFC 32070  
EN 50268-2; IEC 61034-2; VDE 0472 Teil 816 Smoke density
EN 50267-2-1; IEC 60754-1; VDE 0472 Teil 815 Halogen Free
EN 50267-2-2/3; IEC 60754-2; VDE 0472 Teil 813 Corrosivity of gases (Acidity & Conductivity)
EN 50305; NFX 70-100; NFF 63808; TM1-04; BS6853 Toxicity index
NFF 16101; NFF 63808; BS6853 Smoke index

FRL-TW-05SU 300/500 V

NOMINAL CROSS SECTIONAL AREA

NUMBER X NOMINAL DIAMETER OF WIRE

DIAMETER

THICKNESS OF INSULATION

OVERALL DIAMETER

WEIGHT

RESISTANCE OF CONDUCTOR AT 20°C

mm2

mm

min

max

min

min

max

max

mm

mm

mm

mm

mm

kg/km

Ω/km

0.5

19 x 0.18

0.80

0.95

0.18

1.15

1.45

7

40.1

0.75

37 x 0.16(a)

1.00

1.15

0.18

1.35

1.65

8

26.7

1.0

37 x 0.18(a)

1.10

1.30

0.18

1.45

1.80

10

20.0

1.5

37 x 0.23(a)

1.45

1.65

0.22

1.95

2.30

20

13.7

2.5

37 x 0.30(a)

1.85

2.15

0.28

2.50

2.85

25

8.21

-This cable may be supplied in 19 strand conductor providing all product performance requirements in the specification are met

30/50V Multicore RSE/STD/024 Part 6 Rolling Stock Type VII Cable
Cross- sectional Area        1.0mmsq -1.5mmsq
Voltage rating             30/50V
Conductor                   Flexible Stranded Tinned Copper
Number of cores            12-42
Conductor class            IEC 60228 Class 5
Insulation                   Cross linked EPR rubber type EI 107, Standard Wall
Jacket                     Cross linked EVA rubber type EM 104
Fire standard              IEC 332-3C,IEC754;IEC1034-1/2
 
No of Cores/Pairs
Cross Sectional Area(mm sq)
Number and Nominal Diameter of Strands(mm)
Voltage Rating(V)
Nominal Overall
Diameter (mm)
Nominal Weight (kg/km)
12 Core
1.0
32/0.2
30/50
20.25
309.0
42 Core
1.5
30/0.25
30/50
38.35
1661.0