Product Main

Specifications

Without the effects of viscosity, temperature, pressure, density, it may determine the conductivity of the fluid.
 
Sensor:
Model: DM43, DM47, DM41, DM48
Ex-Design: DM43: No; DM47: Exd[ia] iamIICT5; DM41: No; DM48: Exd[ia] iamIICT5
Pressure class: Standard: 0. 6-4. 0 (divide according to calibre)
Special: according to demands of users
Flange material: Carbon steel, stainless steel
Liner: Rubber, PTFE, PFA and so on.
Electrode Material: 316, 316L, Hb, Hc, titanium, tantalum, platinum-iridium, etc
Grounding electrode(ring) material: 316, 316L, Hb, Hc, titanium, tantalum, platinum-iridium, etc.
Conductivity: ≥ 5uS/cm
Fluid temperature: -40oC ~ +180oC (PTFE lining), -25oC ~ +65oC (Rubber lining)
Protection class: IP67, IP68
 
Converters
Supply Power: 24VDC or 220VAC
Signal output: Electric current 4-20mA, frequency output, pulse output
Power consumption: ≤10W (AC power supply); ≤6W (DC power supply)
Status display: LCD,instant and accumulation
Ambient condition: Ambient temperature: -20o C~60oC; Relative humidity: 5%~90%
Accuracy: +/-0. 5% rate ( standard), +/-0. 2% rate (high accuracy )
Repeatability: +/-0. 2% rate
Measuring range: Recommended range of use: 0. 5m/s~10m/s continuous adjustable
Maximum range of use: 0. 01m/s~15m/s continuous adjustable
Excitation: Frequency excitation 6. 25, 12. 5, 15, 25, 30HZ
Communication: Hart communication (option), RS485 communication (option) or Field bus
Protection class: IP67or IP68
Ex-Design: DM43: No; DM47: Exd[ia] iamIICT5; DM41: No; DM48: Exd[ia] iamIICT5
Cable Connection: M20*1. 5或1/2” NPT
Housing: Cast aluminum