V-CONE Flow meter is the same as traditional differential pressure flow meter, three valve block, the primer pressure, differential pressure transmitter, computer components standard flow volume flow measurement system. For gases and steam, and so compressible medium, it can give an additional temperature and pressure compensation, compose mass flow measurement system.
Principle: Differential pressure-type (Bernoulli's Principle)
1) Media Measurement: Gas / liquid
2) Diameters range: 13 ~ 3000mm
3) Application temperature: ~700 oC
4) Application of pressure: ~400bar
5) Straight pipe requirements: Former 3D after 1D
6) Precision grade: 0. 5%
7) Range Proportion: 15: 1
8) Pressure loss: Small
9) HART function: There are (with transmitter)
10) Installation: Plug-in/Piped
11) The most suitable applications: Medium dirty; Less than straight pipe
12) High precision; Small diameter gas or oil