Model | WS12000LTA3 |
Rated frequency Hz | 50 60 |
Rated output power kVA | 11 12 |
Max. power kVA | 12 13 |
Rated voltage V | 400/230 416/240 |
Rated current A | 15.9 16.7 |
Phase No. | Three |
Power factor | 0.8lag |
Insulation | F |
Pole No. | 2 |
Exciting way | Brush, exciting-self voltage-constant with AVR |
Panel type | Intelligent |
Output socket | Three-phase socket, single-phase socket |
DC12V output | 12V, 8.3A |
DimensionsL×W×H mm | 1100×660×740 |
Net weight Kg | 245 |
Noise 7mdB(A) | 70 |
Structure type | Fully closed |
Engine model | R2V840 |
Type | V-twin, two-cylinder, four-stroke, DI |
Cylinder No. bore ×stroke mm | 2-86×72 |
Total displacement ml | 836 |
Rated power kW/ rated speed r/min | 11/3000 12/3600 |
Compressed ratio | 20:1 |
Cooling way | Air-cooled |
Lubricating way | Pressure & splashing |
Starting way | Electric |
Fuel used | 0summer-10winter-35cold winterlight diesel |
Oil used | SAE10W30 CD grade above |
Lubricating oil capacity L | 1.7 |
Starting motor capacity V-kW | 12V 1.4kW |
Dynamo capacity V-A | 12V 10A |
Battery capacity V-Ah | 12V 35AH |
Fuel consumption g/kW.h | ≤280 ≤320 |
Fuel tank capacity of the generator L | 21 |
Continuous operation time of the generator H | 7.5 |
Features:
1. Comparing other generators with same output, it is of compact structure (1100*660*740mm), light weight (248kg)and reliable performance.
2. Adopting the technique of new patented design structure
Our company has adopted the technique of new-patented design structure to separate fully cold & heat wind passages in inner housing. It makes the generator output be no power drop for long-period operation.
The wind passage with special labyrinth design makes the generator be of lower noise.
3. Application of intelligent control panel
Our company has adopted new-type intelligent control panel, which facilitate the operation. The operator can know the real working condition of the generator from panel reading. There are more than ten protections of the generator in the panel, such as protections of frequency, voltage, current, low oil pressure, low fuel level, and electric fan adjusting the temperature automatically when inner-housing temperature over 60, and automatic unload before engine stopped each time etc. The diesel/water separator can ensure the fuel quality.
4. Application of automatic shifting switch (ATS)
Our company can fit ATS based on customer requirement, which can make the generator be automatic operation without the operator on the spot. When city power net breaks down, ATS can deliver the signal in shortest time to the generator for starting. When city power net is recovered, ATS can shift the power from the generator to city power net and the generator will be automatically stopped later.
5. Application of new-generation intelligent AVR
Our company has adopted new-generation intelligent AVR (automatic voltage-constant) to make the output voltage be steady.