Gas Boiler Series
Main Features:
1>. Low circulation water pressure protection: Minimum 0.5Mpa.
2>. Hot water temperature exceptional protection: Maximum 3oC/sec.
3>. Anti-frequently start ignition: An interval 3 minutes between next start.
4>. Multiple frost protection:
(A) ≤8oC pump circulate 30min.
(B) ≤5oC heating for 5min.
(C) lgnition fail no gas supply, pump circulate 24hrs
5>. Lighting strike protection.
6>. Deflagration protection: Increase gas flow automatically when gas pressure too low (lgnition time exceptional).
7>. Anti-lock water pump: 30 sec. /24hrs. Circulate automatically during summer.
8>. Ultra quite operation: C. E. Approved motor fan and pump.
9>. Self-diagnostic: Resume work from simply breakdown.
10>. Multifunctional user interface:
(A) Max. ~ Min. Gas flow control.
(B) The circulation water temperature difference control between outlet and return water.
(C) Hot water temperature exceptional protection control.
11>. Switch radiator heating and under floor heating.
12>. Switch water pump between 3 min. Circulatinig after intermittence 8 min. And 24 hrs during stand by.
13>. Adustable the circulation water temperature difference between outlet and return water (10~30) during stand by.
14>. Domestic hot water priority function.
15>. Avoid to rising temperature of domestic hot water when re-start tap by circulating hot water automatically after turn off the tap.
16>. 20sec. Exhaust waste gas before and after combustion
(3 sec. For domestic hot water funtion).
17>. Technical Parameters:
Model | Unit | JLG28-BV6 | ||
Rated Heat Input | Kw | 28 | ||
Rated Output Power | Kw | 25 | ||
Heat Efficiency | % | > 90 | ||
Max Power Input | w | 125 | ||
Power Supply | AC220V/50HZ | |||
N. W. | Kg | 37 | ||
External Dimensions | mm | 740X400X300 | ||
Index Of Protection | IP | IPX4 | ||
Gas Type Gas Pressure Gas Consumption | LPG | Rated Gas Pressure | Pa | 2800 |
Gas Consumption | Nm3/Kwh | 0. 035 | ||
NG | Rated Gas Pressure | Pa | 2000 | |
Gas Consumption | Nm3/Kwh | 0. 1 | ||
Central Heating | Output Power Range | Kw | 7. 5~25 | |
Water Temperature Range | ℃ | 40~80 | ||
Reference Heating Square | m2 | 140~220 | ||
Water Working Pressure Range | Bar | 0. 8~2. 7 | ||
Heating Return Safety Valve Opening Water Pressure | Bar | 3 | ||
Pump Lift | M | 6 | ||
Expansion Vessle Capacity | L | 6 | ||
DHW (Domestic Hot Water) | Output Power Ranger | Kw | 7. 5~25 | |
DHW Temperature Set Range | °C | < 65 | ||
Max DHW Output △t=25K | Kg/min | 14 | ||
Operation Pressure DHW Range | Bar | 0. 3~7 | ||
Fittings | Central Heating Fittings | Inch | G3/4 | |
DHW Fittings | Inch | G1/2 | ||
Gas Fittings | Inch | G3/4 | ||
Coaxial Flue Pipe | Straight | mm | F60/100 | |
Elbow | mm | F60/100 | ||
Max Permissible Flue Lengths | Max Horizontal Flue Length (100cm) | cm | 95cm | |
Max Vertical Flue Length (100cm) | cm | 14cm | ||
Flue Pipe Length Reduction For Elbows | 90° Elbow F60/100mm | m | 1. 0m | |
45° Elbow F60/100mm | m | 0. 5m |