Product Main

Specifications

Gas Boiler Series
Main Features:
1>. Low circulation water pressure protection: Minimum 0.5Mpa.
2>. Hot water temperature exceptional protection: Maximum 3oC/sec.
3>. Anti-frequently start ignition: An interval 3 minutes between next start.
4>. Multiple frost protection:
(A) ≤8oC pump circulate 30min.
(B) ≤5oC heating for 5min.
(C) lgnition fail no gas supply, pump circulate 24hrs
5>. Lighting strike protection.
6>. Deflagration protection: Increase gas flow automatically when gas pressure too low (lgnition time exceptional).
7>. Anti-lock water pump: 30 sec. /24hrs. Circulate automatically during summer.
8>. Ultra quite operation: C. E. Approved motor fan and pump.
9>. Self-diagnostic: Resume work from simply breakdown.
10>. Multifunctional user interface:
(A) Max. ~ Min. Gas flow control.
(B) The circulation water temperature difference control between outlet and return water.
(C) Hot water temperature exceptional protection control.
11>. Switch radiator heating and under floor heating.
12>. Switch water pump between 3 min. Circulatinig after intermittence 8 min. And 24 hrs during stand by.
13>. Adustable the circulation water temperature difference between outlet and return water (10~30) during stand by.
14>. Domestic hot water priority function.
15>. Avoid to rising temperature of domestic hot water when re-start tap by circulating hot water automatically after turn off the tap.
16>. 20sec. Exhaust waste gas before and after combustion
(3 sec. For domestic hot water funtion).
17>. Technical Parameters:
Model Unit JLG36-BV12
Rated Heat Input Kw 36
Rated Output Power Kw 32. 04
Heat Efficiency % > 88
Max Power Input w 180
Power Supply   AC220V/50HZ
N. W. Kg 48
External Dimensions mm 800X460X340
Index Of Protection IP IPX4
Gas Type Gas Pressure Gas Consumption LPG Rated Gas Pressure Pa 2800
Gas Consumption Nm3/Kwh 0. 035
NG Rated Gas Pressure Pa 2000
Gas Consumption Nm3/Kwh 0. 1
Central Heating Output Power Range Kw 9. 57~32. 04
Water Temperature Range 40~80
Reference Heating Square m2 180~280
Water Working Pressure Range Bar 0. 8~2. 7
Heating Return Safety Valve Opening Water Pressure Bar 3
Pump Lift M 7
Expansion Vessle Capacity L 10
DHW (Domestic Hot Water) Output Power Ranger Kw 9. 57~32. 04
DHW Temperature Set Range °C < 65
Max DHW Output △t=25K Kg/min 18
Operation Pressure DHW Range Bar 0. 3~7
Fittings Central Heating Fittings Inch G3/4
DHW Fittings Inch G1/2
Gas Fittings Inch G3/4
Coaxial Flue Pipe Straight mm F60/100
  Elbow mm F60/100
Max Permissible Flue Lengths Max Horizontal Flue Length (100cm) cm 95cm
Max Vertical Flue Length (100cm) cm 14cm
Flue Pipe Length Reduction For Elbows 90° Elbow F60/100mm m 1. 0m
45° Elbow F60/100mm m 0. 5m