Product Main

Specifications

Features Specifications: Hard Start Capacitors Supco SPP5 SPP6 SPP7 SPP8 SPP9 SPP5E SPP6E SPP7E SPP8E

This product is used for starting air conditioner or heat Pump compressors (both reciprical and scroll type) that Need an extra "jolt" of electricity to get started. Equipment That needs a hard-start capacitor: Heat pump or condensers split-systems that have a (TXV) Installed on them.Old heat pump or condensers that are mechanically stuck And not operating

If you have a new or old compressor that isn't starting, Try installing this hard-start capacitor before you do anything Else. The parts inside a compressor might be too physically tight To move, or on systems with a TXV where the refrigerant pressures Are higher on start-up, and need an extra "kick" of energy to get Started. This hard-start capacitor provides that extra jolt of Energy. Capacitor is very easy to install (takes about 1 minute) And will remain permanently in the equipment.

Features Specifications: hard start kit (refrigeration, HVAC)

Features:

1) Increases starting torque up to 500%

2) UL certified

3) Totally solid state integrated design

4) Fast, easy wires installation

5) Three mounting options: Clip, screw, capacitor bracket

6) Individually packed

Replaces: GEM HS600, HS650, HS800, HS410, HS810, SUPCO SPP5, SPP6

Refrigeration spare parts, refrigerator parts, air conditioner spare Parts, hard start kit(SPP5, SPP6, SPP8E, HS410, HS810, and so on), Potential relay, thermostat(Danfoss type, Ranco type, Ego type, Supco Type and so on).

HS810 1/12 thru 1/5 115

HS410 1/4 and 1/3 115

HS600 1/2-5 115

HS650 1/4 and 1/3 115

EVP4E 1/8 - 1 90-130V

EVP5E 1/3 - 2 90-277V

EVP6E 1/2 - 3 90-277V

EVP7E 1 - 4 90-277V

EVP8E 1 - 5 90-277V

EVP9E 1 - 5 90-277V

EVP10E 3 - 5 90-277V

Part no. Horsepower voltage

Hs600 1/2 - 5 277

Hs650 1/2 - 10 277

Hs410 1/4 and 1/3 115

Hs810 1/12 thru1/5 115

Spp8 10 288

Part No. Increased Torque Voltage

SPP5 270 Ounce Inches 115-230

SPP6 390 Ounce Inches 115-230

SPP Series Capacitor Operation Voltage Recommended Range Increase in Torque (%)

SPP5 43-52uf 115-288VAC 1/2HP-10HP 300%

Spp6 130~156 uf 115-288VAC 1/2HP-10HP 500%

SPP8 189-227uf 115-288VAC 1/2HP-10HP 690%

We can apply hard start kit by your requestment.

Part No. Voltage(V) Horsepower(Hp)

HS600 115-277 1/2-5

HS650 115-277 1/2-10

HS410 115-277 1/ 4 and 1/3

HS810 115-277 1/12 thru 1/5

SPP8 120-288 10