Product Main

Specifications

Fischer-Porter Intelligent Electromagnetic Flowmeter

Pother industries. Without the effects of viscosity, temperature, pressure, density, it may determine the conductivity of the fluid.

Characteristics

1) For harsh operating condition, if high concentration paper pulp or low electrical conductivity fluid is mixed, it may realize high standard stable measurement.

2) The measurement is not affected by the fluid density, viscosity, temperature and pressure change.

3) Full digital quantity processing; the anti-interference capability is strong

For more details, please feel free to contact us.

Sensor
Model DM43 DM47 DM41 DM48
Ex-Design No Exd[ia]iamIICT5 No Exd[ia]iamIICT5
Size DN3 - DN2000
Pressure class Standard: 0. 6-4. 0 (divide according to calibre)
Specialaccording to demands of users
Flange material Carbon steel, stainless steel
Liner Rubber, PTFE, PFA and so on.
Electrode Material 316, 316L, Hb, Hc, titanium, tantalum, platinumiridium, etc
Grounding electrode (ring) material 316, 316L, Hb, Hc, titanium, tantalum, platinumiridium, etc.
Conductivity ≥ 5μS/cm
Fluid temperature -40oC ~ +180oC PTFE lining , -25oC ~  +65oC Rubber lining
Protection class IP67, IP68
Converters
Supply Power 24VDC or 220VAC
Signal output Electric current 4-20mA, frequency output, pulse output
Power consumption ≤10W (AC power supply), ≤6W (DC power supply)
Status display LCD, instant and accumulation
Ambient condition Ambient temperature: -20oC ~ 60oC; Relative humidity: 5% ~ 90%
Accuracy ±0. 5% rate (standard), ±0. 2% rate (high accuracy )
Repeatability ±0. 2% rate
Measuring range
Recommended range of use: 0. 5m/s10m/s continuous adjustable Maximum range of use: 0. 01m/s15m/s continuous adjustable
Excitation Frequency excitation 6. 25, 12. 5, 15, 25, 30HZ
communication Hart communication (option), RS485 communication (option) or Field bus
Protection class IP67 or IP68 IP67 or IP68
Ex-Design no Exd[ia]iamIICT5 no Exd[ia]iamIICT5
Cable Connection M20x1. 5, 1/2'' NPT
Housing Cast aluminum