Product Main

Specifications

Product Description
REF NO.                          SPECIFICATION
                               Standard / Leads  Patient end terminal / Material / Defibrillation withstand 
EA052S5A AHA,           5LD:A,    SNAP,      TPU,  
EA052C5A AHA,           5LD:A,    CLIP,        TPU,    
EA052S3A AHA,           3LD:A,    SNAP,      TPU,    
EA052C3A AHA,           3LD:A,    CLIP,        TPU,    
EA052S5I IEC,            5LD:I,     SNAP,      TPU,   
EA052C5I IEC,            5LD:I,     CLIP,        TPU,    
EA052S3I IEC,            3LD:I,     SNAP,      TPU,    
EA052C3I IEC,            3LD:I,     CLIP,        TPU,   
Compatible Models No.

SIEMENS MEDICAL:
Sirecust Series 400, 500, 600,
Serie 700, 900, 1200,
Sirecust 341/610/620/630/720/722
Sirecust 730/732/900/960/961/1260
Sirecust 1281/1801/400/-500
ECG Monitor, Polymed Modul,
Modulbox Sirem

Specifications.

Storage and transport environment: -5~+40℃
Operating temperature: 0~+40℃
Humidity
Operating/Storage/Transportation 0% to 80% non condensing Altitude
Hyperbaric Pressure 86kPa~106kPa
Biocompatibility: All patient contact materials are latex free and have been tested according to ISO 10993-5,ISO 10993-10.


Instrument Connectors
An extensive variety of connector solutions is available. All have flex-reliefs for durability.

Trunk Cables
The 3 meter (10 ft) patient cable assembly uses shielded, low noise cable to minimize tribo-electric noise and electrical nterference. Flex-reliefs at both the connector and cable yoke provide flexibility and reduce continuity breakage.these cable yokes are labeled to clearly depict both AHA and IEC color coding for quick and easy lead attachment. Part numbers and lot numbers indicate equipment compatibility and product traceability.

Lead wires
Low profile, insert molded snap or pinch connectors offer patient comfort and secure attachment to snap electrodes. The snap termination’s ergonomic, teardrop design reduces tangling at the patient end connector. Grabber and mini clip terminations have dual sided metal contacts to provide the connection.

 

Advantages

 

 

Product Facts
Fully shielded patient cable and lead wires
High density interface allows compact size, light weight
Keyed lead wire termination to provide correct orientation
Latex-free

 

We also offer many Patient monitor ECG Cables with Leadwires, Elextrocardiograph ECG Cable with Leadwires, Holter Recorder ECG Patient Cable and Leads, Non-Invasive Blood Pressure Cuff & Tubes, IBP Cable and Pressure Transducers, Medical Temperature Probes, Medical Temperature probes, Instrument Connector and Socket, EEG Electrodes and cord, ESU pencil and Patient Return Plate Cable, Raw medical cable and wires. and at the same time, OEM and ODM are high welcome!