【Characteristic】
Early strength and high strength:Compressive strength can reach 50MPa 1-3 days after grouting.
Enduring high strength:No later strength decline
Flat gravitational flow:Mortar flows automatically without opening to standard height.
Micro expansion:No shrinkage in casting body, ensuring the long-term safe operation of the equipment
Anti-peeling:New and old interfaces are combined firmly.
Oil penetration resistance:Dense and oil penetration proof, applicable to the oil stain environment at the stand.
Weather resistance:Long-term safe application within -40~400℃.
【Property】
Category
Item |
Super-fluidity Type |
Heat-proof High Strength Type |
Reinforcement Planting Anchoring Type |
Gravity Self-leveling Type |
Quick Hardening High Strength Type |
Metal Fiber Ultra-high Strength Type | |
Model |
LGM-X |
LGM-R |
LGM-Z |
LGM-L |
LGM-S |
LGM-G | |
Compressive strength(MPa) |
1d |
≥20 |
≥20 |
≥15 |
≥30 |
≥15* |
≥45 |
3d |
≥40 |
≥40 |
≥25 |
≥40 |
≥20** |
≥60 | |
28d |
≥60 |
≥70 |
≥50 |
≥70 |
≥60 |
≥100 | |
Max |
80 |
80 |
70 |
90 |
80 |
120 | |
Vertical expansion rate(%) |
≥0.02 |
≥0.02 |
≥0.02 |
≥0.02 |
≥0.02 |
≥0.02 | |
Flow rate(mm) |
≥340 |
≥270 |
≥270 |
≥290 |
≥280 |
≥260 | |
Water demand(%) |
13~16 |
12~14 |
12~14 |
13~15 |
12~14 |
12~14 | |
Casting demand(Kg/m3) |
2000~2100 |
2100~2200 |
2100~2200 |
2100~2200 |
2100~2200 |
2100~2200 | |
Range of Application |
Grouting in equipment foundation plate gap and post-tensioned pre-stressing concrete structure pore canal |
Safe working under the environment below very high temperature (600℃) |
Concrete structure reinforcing and planting anchoring |
Airport runway and bridge deck mending, industrial factory building ground grouting |
Anchoring anchor planting, pavement mending, quick mending of equipment foundation
|
Antiknock construction, heavy machinery foundation and other heavy industries |
* indicates compressive strength after 3h; ** indicates compressive strength after 6h.
All the above data was measured under standard environment condition and can be properly adjusted in accordance with engineering requirement.