Features
With excellent rebound property, when reachs the destination, will rebound almost to the original level in 24 hours after been unpacked.
Usage:
Heat preservation for steel structure building
Heat insulation for wall and roof of house to save energy
For indoor partition wall,Train compartment Special specification can be made upon on request.
Heat preservation for steel structure building
Heat insulation for wall and roof of house to save energy
For indoor partition wall,Train compartment Special specification can be made upon on request.
|
Product |
Length
(mm) |
Width(Diameter)
(mm) |
Thickness
(mm) |
Density
(kg/m3) |
Notice |
|
Blanket (felt)
in roll |
6000-30000 |
1200 (600/400/300) |
25-200 |
10-48 |
Black/pink available |
|
Boards (Slab) |
1200-2200 |
600-1200 |
20-100 |
24-100 |
Black/pink available |
|
Batts |
1200-4800 |
600-1200 |
25-200 |
10-48 |
|
|
Super wool |
6000-30000 |
1200/600/500 |
25-150 |
10-48 |
5-6% binder |
|
Glass wool with FSK |
Including aluminum foil, fiber cloth, fiber tissue, polypropylene, double alum. foil, kraft |
One side and two sides | |||
|
Twin blanket (felt) in roll |
6000-15000 |
1200 |
50-100 |
10-48 |
|
|
Pipe Sections |
1000 |
15-400 |
20-100 |
45-90 |
|
Main index of physical properties:
|
tem |
Unit |
Index |
Standard |
|
Density |
kg/m3 |
10-100 |
GB/T 5480.3-1985 |
|
Average fiber dia. |
um |
5.5 |
GB/T 5480.4-1985 |
|
Water content |
% |
<1 |
GB/T 3007-1982 |
|
Reaction of fire
classification |
|
A1 |
EN13501-1:2007 |
|
Average Tf |
3.60 |
EN ISO 1182 | |
|
Averaged sustained
flaming |
S |
0.00 |
EN ISO 1182 |
|
Average mass loss |
% |
2.40 |
EN ISO 1182 |
|
Product PCS |
MJ/kg |
1.12 |
EN ISO 1716 |
|
Reshrinking temp |
>260 |
GB/T 11835-1998 | |
|
Thermal conductibility |
w/m.k |
0.032-0.044 |
EN13162:2001 |
|
Hydrophobicity |
% |
>98.2 |
GB/T 10299-1988 |
|
Moisture rate |
% |
<5 |
GB/T 16401-1986 |
|
Sound absorption
coefficient |
|
1.03 product reverberation
Method (24kg/m3 2000HZ) |
GBJ 47-83 |
|
Slag inclusion
content |
% |
<0.3 |
|