Product Main

Specifications

Hot Water Boiler Series
Main Features:
1>.Low circulation water pressure protection: Minimum 0.5Mpa.
2>.Hot water temperature exceptional protection: Maximum 3oC/sec.
3>.Anti-frequently start ignition: An interval 3 minutes between next start.
4>.Multiple frost protection:
     (A)≤8oC pump circulate 30min.
     (B)≤5oC heating for 5min.
     (C)lgnition fail no gas supply, pump circulate 24hrs
5>.Lighting strike protection.
6>.Deflagration protection: Increase gas flow automatically when gas pressure too low (lgnition time exceptional).
7>.Anti-lock water pump: 30 sec./24hrs. circulate automatically during summer.
8>.Ultra quite operation: C.E. approved motor fan and pump.
9>.Self-diagnostic: Resume work from simply breakdown.
10>.Multifunctional user interface:
      (A)   Max.~ Min. gas flow control.
      (B)   The circulation water temperature difference control between outlet and return water.
      (C)   Hot water temperature exceptional protection control.
11>.Switch radiator heating and under floor heating.
12>.Switch water pump between 3 min. circulatinig  after intermittence 8 min. and 24 hrs during stand by.
13>. Adustable the circulation water temperature difference between outlet and return water (10~30) during stand by.
14>.Domestic hot water priority function.
15>.Avoid to rising temperature of domestic hot water when re-start tap by circulating hot water automatically after turn off the tap.
16>.20sec. exhaust waste gas before and after combustion
      (3 sec. For domestic hot water funtion).
17>.Technical Parameters:
Model Unit JLD26-BV10
Rated Heat Input Kw 26
Rated Output Power Kw 23.1
Heat Efficiency % >90
Max Power Input w 90
Power Supply   AC220V/50HZ
N.W. Kg  
External Dimensions mm  
Index Of Protection IP IPX4
Gas Type
Gas Pressure
Gas Consumption
LPG Rated Gas Pressure Pa 2800
Gas Consumption Nm3/Kwh 0.035
NG Rated Gas Pressure Pa 2000
Gas Consumption Nm3/Kwh 0.1
Central Heating Output Power Range Kw 6.9~23.1
Water Temperature Range  
Reference Heating Square m2 110~150
Water Working Pressure Range Bar 0.8~2.7
Heating Return Safety Valve
Opening Water Pressure
Bar 3
Pump Lift M 6
Expansion Vessle Capacity L 6
DHW
(Domestic Hot Water)
Output Power Ranger Kw 6.9~23.1
DHW Temperature Set Range °C <65
Max DHW Output △t=25K Kg/min 13
Operation Pressure DHW Range Bar 0.3~7
Fittings Central Heating Fittings Inch G3/4
DHW Fittings Inch G1/2
Gas Fittings Inch G3/4
Coaxial Flue Pipe Straight mm F100
  Elbow mm F100
Max Permissible
Flue Lengths
Max Horizontal Flue Length (100cm) cm 95cm
Max Vertical Flue Length (100cm) cm 14cm
Flue Pipe Length
Reduction For Elbows
90° Elbow F60/100mm m 1.0m
45° Elbow F60/100mm m 0.5m