At the materials of Gap Impact Testing, in the progress of the test, how to process the V-type (or U-type) gap remains the only obstacle. This machine is Manual structure, can according to user requirement to check V-type, U-type 2mm, 3mm and 5mm. Both of these contribute to the easy and realizable operation of the machine. The processed V-type and U-type meet requirements of GB 229-94 Metallic materials -Charpy notch impact test and ASTM E23, EZ3, ISO18 both home and abroad; And the processed U-type (3mm) meet requirement of DIN50115 of DVM samples demand.
Main Technical Parameters:
1. Process Samples Gape: V (GB229-94, ISO148); U (2mm, GB229-94)
2. Size of Samples: 10*10* 55 mm
3. Stroke of Broach: 350 mm
4. Broaching Speed: 2.5 mm/min
5. Size: 350*350*700(L*W*H)mm
6. Weight: 100 Kg