1.Application:
General-purpose rubber flexible cable is used for household electrical appliance, electrical tools and various mobile electrical equipment of AC rated voltage 300/500V.
2.Standard: IEC245-1994/ GB5013-1997/ JB8735-1998
3.Rated voltage: Uo/U 300/500V
4.Insulation: Rubber
5.Sheath: Rubber
6.Temperature rating: Conductor operating temperature should not exceed 65 °C
7.Nominal cross sectional area of conductor: 0.75-2.5 mm2(two cores to five cores)
8.Specification:
|
Nominal cross
sectional area
of conductor( mm2) |
Nominal
Thickness
of insulation(mm) |
Nominal
Thickness
of jacket(mm) |
Average
O.D.(mm) |
Max Conductor
Resistance at
20oC Ω/km | ||
|
Min |
Max |
Copper
conductor |
Tinned round
copper wire | |||
|
2x0.75 |
0.6 |
0.8 |
6.0 |
8.2 |
26.0 |
26.7 |
|
2x1.0 |
0.6 |
0.9 |
6.6 |
8.8 |
19.5 |
20.0 |
|
2x1.5 |
0.8 |
1.0 |
8.0 |
10.5 |
13.3 |
13.7 |
|
2x2.5 |
0.9 |
1.1 |
9.5 |
12.5 |
7.98 |
8.21 |
|
3x0.75 |
0.6 |
0.9 |
6.5 |
8.8 |
26.0 |
26.7 |
|
3x1.0 |
0.6 |
0.9 |
7.0 |
9.2 |
19.5 |
20.0 |
|
3x1.5 |
0.8 |
1.0 |
8.6 |
11.0 |
13.3 |
13.7 |
|
3x2.5 |
0.9 |
1.1 |
10.0 |
13.0 |
7.98 |
8.21 |
|
4x0.75 |
0.6 |
0.9 |
7.1 |
9.6 |
26.0 |
26.7 |
|
4x1.0 |
0.6 |
0.9 |
7.6 |
10.0 |
19.5 |
20.0 |
|
4x1.5 |
0.8 |
1.1 |
9.6 |
12.5 |
13.3 |
13.7 |
|
4x2.5 |
0.9 |
1.2 |
11.0 |
14.0 |
7.98 |
8.21 |
|
5x0.75 |
0.6 |
1.0 |
8.0 |
11.0 |
26.0 |
26.7 |
|
5x1.0 |
0.6 |
1.0 |
8.5 |
11.5 |
19.5 |
20.0 |
|
5x1.5 |
0.8 |
1.1 |
10.5 |
13.5 |
13.3 |
13.7 |
|
5x2.5 |
0.9 |
1.3 |
12.5 |
15.5 |
7.98 |
8.21 |