Product Main

Specifications

Brief introduction:
ETCR9000 Series H/L Voltage Clamp Meter has broken through the traditional structure, which is specially well-designed for measuring high voltage current, adopting the latest CT technology and integrated mask digital technology, formed by composition of a special use clamp meter with a high-voltage insulation rod, as to ETCR9000A type -- infrared transmission of test data, also equipped with receivers, which can monitor the tested data in a long distance on real-time. If not using an insulation rod, it can be also used as a high precision low-voltage clamp meter, or an alternating current meter, which can accurately measure 1mA of current or leakage current.
ETCR9000 Series H/L Voltage Clamp Meter has an innovative integrated design between transducer clamp and transducer domain, ensuring the high-precision, high-reliability, and high-stability on constant test perennially.
ETCR9000 Series H/L Voltage Clamp Meter is connected with insulation rod, which can be used for measuring high voltage current that is below 23KV, on-line current measurement, also having peak maintenance, data preservation, data storage, infrared transmission and other functions, and its special clamp meter can make it easier for clamping or evacuating the tested wire through pressing or pulling back the insulation rod, time-saving and fast, widely used in transformer substation, power plant, industrial and mining enterprises as well as the inspection station and electrician maintenance departments for electrical current detection and field electrical operations. It can also replace the H/L voltage transforming ratio tester, that is, to detect the high and low current for primary circuit and secondary circuit separately, and then calculate to conclude the change of high and low pressure. The insulation rod is light and convenient, with the advantages of anti-moisture, high temperature resistance, anti-impact, bending resistance, high insulation, flexibility and other characteristics.
Mode series
Mode
Range
Resolution
Clamp mouth
Storable data
explanation
ETCR9000
1mA~600A
1mA
φ48mm
99grounds
Base mode
ETCR9000A
1mA~600A
1mA
φ48mm
99grounds
Infrared Transmission mode
Technical specifications
Function
High voltage AC current measurement, low voltage AC current, leakage current measurement, on-line AC current supervision.
Battery supply
DC6V alkaline dry battery (AAA×4)
Test mode
Clip –on CT,integral mode
*Transmission Method
Infrared Transmission, the maximum distance for direct transmission is about 10m.
* * Transmission distance
10m(maximum)
Display dimensions
4 digital LCD display, backlight function, suitable for dark place.
LCD dimensions
47mm×28.5mm
dimensions
Width *height* thickness:76mm×255mm×31mm
Clamp mouth
φ48mm
Sampling Rate
Twice per second
Measuring Scope
1mA~600A(50/60Hz automatic)
Resolution
1mA
Measuring range
10A/600A, second-range manual switch,automatic switch in all ranges
Measuring accuracy
(23℃±5℃,80%RH below)
1mA~299mA: ±1%±3dgt
300mA~10.00A: ±1.5%±5dgt
0.0A~199.9A: ±2%±5dgt
200A~399A: ±2.5%±5dgt
400A~600A: ±3%±5dgt
Circuit Voltage

Test for the circuit below 23KV (operated with insulation rod)

- 5-

Data memory
99 Groups, during storage, the symbol "MEM” gives indication, "FULL” mark will flash to indicate the memory has been full.
Peak Maintenance
The function of automatic capture and maintain the maximum average value, under general test mode, press HOLD button longer till PEAK light is bright, that is, start PEAK test function, also known as peak test.
Data Preservation
Under general test mode, press HOLD button to preserve data, "HOLD” symbol display.
Data look out
"MR”symbol means turn up and down to look out the data is allow.
Overflow display
Outrange overflow display:displayed by "OL A” symbol
*No signal
Indicator
When the receiver has not received transmit signal, it will display "no- -”signal dynamically.
Auto Shut Down
In about 15 minutes after booting, the meter will shut down automatically, in order to decrease the battery consumption.
Battery voltage
When battery voltage reduced to 5V, battery low voltage symbol will filker to remind replacing battery
Meter quality
Tester: About 335g (Including battery), total quality of meter: about 2.5Kg (including insulation rod and battery.)
Working temperature and humidity
-10℃~40℃; 80%Rh below
Storage temperature and humidity
-10℃~60℃; 70%Rh below
insulating bar dimensions
φ32mm ,1m/ Section(5 Sections)
Insulation strength
AC 40KV/rms (Between insulation rod and clamp core)
structure
Anti-Dripping Type II
Mark with"*”is limited to ETCR9000A(Infrared Transmission mode)only.