Brief introduction:
ETCR9000 Series H/L Voltage Clamp Meter has broken through the traditional structure, which is specially well-designed for measuring high voltage current, adopting the latest CT technology and integrated mask digital technology, formed by composition of a special use clamp meter with a high-voltage insulation rod, as to ETCR9000A type -- infrared transmission of test data, also equipped with receivers, which can monitor the tested data in a long distance on real-time. If not using an insulation rod, it can be also used as a high precision low-voltage clamp meter, or an alternating current meter, which can accurately measure 1mA of current or leakage current.
ETCR9000 Series H/L Voltage Clamp Meter has an innovative integrated design between transducer clamp and transducer domain, ensuring the high-precision, high-reliability, and high-stability on constant test perennially.
ETCR9000 Series H/L Voltage Clamp Meter is connected with insulation rod, which can be used for measuring high voltage current that is below 23KV, on-line current measurement, also having peak maintenance, data preservation, data storage, infrared transmission and other functions, and its special clamp meter can make it easier for clamping or evacuating the tested wire through pressing or pulling back the insulation rod, time-saving and fast, widely used in transformer substation, power plant, industrial and mining enterprises as well as the inspection station and electrician maintenance departments for electrical current detection and field electrical operations. It can also replace the H/L voltage transforming ratio tester, that is, to detect the high and low current for primary circuit and secondary circuit separately, and then calculate to conclude the change of high and low pressure. The insulation rod is light and convenient, with the advantages of anti-moisture, high temperature resistance, anti-impact, bending resistance, high insulation, flexibility and other characteristics.
Mode series
|
Mode |
Range |
Resolution |
Clamp mouth |
Storable data |
explanation |
|
ETCR9000 |
1mA~600A |
1mA |
φ48mm |
99grounds |
Base mode |
|
ETCR9000A |
1mA~600A |
1mA |
φ48mm |
99grounds |
Infrared Transmission mode |
Technical specifications
|
Function |
High voltage AC current measurement, low voltage AC current, leakage current measurement, on-line AC current supervision. | |
|
Battery supply |
DC6V alkaline dry battery (AAA×4) | |
|
Test mode |
Clip –on CT,integral mode | |
|
*Transmission Method |
Infrared Transmission, the maximum distance for direct transmission is about 10m. | |
|
* * Transmission distance |
10m(maximum) | |
|
Display dimensions |
4 digital LCD display, backlight function, suitable for dark place. | |
|
LCD dimensions |
47mm×28.5mm | |
|
dimensions |
Width *height* thickness:76mm×255mm×31mm | |
|
Clamp mouth |
φ48mm | |
|
Sampling Rate |
Twice per second | |
|
Measuring Scope |
1mA~600A(50/60Hz automatic) | |
|
Resolution |
1mA | |
|
Measuring range |
10A/600A, second-range manual switch,automatic switch in all ranges | |
|
Measuring accuracy
(23℃±5℃,80%RH below) |
1mA~299mA: ±1%±3dgt | |
|
300mA~10.00A: ±1.5%±5dgt | ||
|
0.0A~199.9A: ±2%±5dgt | ||
|
200A~399A: ±2.5%±5dgt | ||
|
400A~600A: ±3%±5dgt | ||
|
Circuit Voltage |
Test for the circuit below 23KV (operated with insulation rod)
| |
|
Data memory |
99 Groups, during storage, the symbol "MEM” gives indication, "FULL” mark will flash to indicate the memory has been full. | |
|
Peak Maintenance |
The function of automatic capture and maintain the maximum average value, under general test mode, press HOLD button longer till PEAK light is bright, that is, start PEAK test function, also known as peak test. | |
|
Data Preservation |
Under general test mode, press HOLD button to preserve data, "HOLD” symbol display. | |
|
Data look out |
"MR”symbol means turn up and down to look out the data is allow. | |
|
Overflow display |
Outrange overflow display:displayed by "OL A” symbol | |
|
*No signal
Indicator |
When the receiver has not received transmit signal, it will display "no- -”signal dynamically. | |
|
Auto Shut Down |
In about 15 minutes after booting, the meter will shut down automatically, in order to decrease the battery consumption. | |
|
Battery voltage |
When battery voltage reduced to 5V, battery low voltage symbol will filker to remind replacing battery | |
|
Meter quality |
Tester: About 335g (Including battery), total quality of meter: about 2.5Kg (including insulation rod and battery.) | |
|
Working temperature and humidity |
-10℃~40℃; 80%Rh below | |
|
Storage temperature and humidity |
-10℃~60℃; 70%Rh below | |
|
insulating bar dimensions |
φ32mm ,1m/ Section(5 Sections) | |
|
Insulation strength |
AC 40KV/rms (Between insulation rod and clamp core) | |
|
structure |
Anti-Dripping Type II |
Mark with"*”is limited to ETCR9000A(Infrared Transmission mode)only.