RDTP11 Series--- Embedded Modularized Inverter Power Supply
High reliability and modularized structure
Parallel working of multiple machines, realizing the N+1 backup working
Saving investment and increasing the utilization factor of equipment
Flexible running modes – mains supply preferential power supply or inverter preferential power supply
Unique AC machine paralleling technique, easy and convenient capacity expansion and maintenance
Standard structure design and abundant display information
Excellent anti-interference performance
Intelligent RS232 communication interface
Parallel working of multiple machines, realizing the N+1 backup working
Saving investment and increasing the utilization factor of equipment
Flexible running modes – mains supply preferential power supply or inverter preferential power supply
Unique AC machine paralleling technique, easy and convenient capacity expansion and maintenance
Standard structure design and abundant display information
Excellent anti-interference performance
Intelligent RS232 communication interface
Specifications
Type |
RDTP11-06 |
RDTP11-012 |
Output capacity |
6KVA |
12KVA |
Number of modules |
3 |
6 |
Dimensions (W*H*D mm) |
482×176×460 |
482×308×460 |
Operating Environment
Operating temperature |
-5°C-40°C |
Storage temperature |
-25°C-60°C |
Height above sea level |
<=1500 meters |
Relative humidity |
5%-95% |
AC Input
Voltage range |
220V±20% |
Input mode |
single-phase |
Frequency |
45HZ-55HZ |
Power factor complying with |
EN605552 |
DC Output
Rated voltage of input |
48VDC 110VDC 220VDC |
Input voltage range |
40V-57V 92V-132V 187V-264V |
Reflected relative broadband frequency noise current at the input end |
<10% |
Reflected relative weighted noise current at the input end |
<1% |
Inverter Output
Output voltage |
220±2% |
Power factor |
0.8 (inductive load, capacitive load) |
Voltage distortion |
<=3% for linear load, <=5% for non-linear load |
Frequency |
following the frequency of mains supply and the phase difference is less than 3 degrees when mains supply is in the rang of 50Hz±10%; being in the rang of 50Hz±0.2% when mains supply exceeds the limits or battery supply |
Peak factor |
3:1 |
Overall efficiency |
>=88% |
Current equalizing precision |
<=5% |
Switching time |
<4ms |
Transient rang of dynamic response its output voltage |
=2% when the load changes within the range of 10% ~ 100% or 100% ~ 10%. |
Noise |
(1m)< =45DB |
Display mode |
240×128 lattice LCD |
Electromagnetism compatibility |
EN50091-2 CLASS B |
Anti-interference |
IEC 1000-4-2.3.4.5.11 |
Safety standard |
CCEE (EN60950) |