Charging water systems solenoid valves
Model | FSK-20 | |||
Action way | Pilot type | |||
Type | NC | |||
Working pressure | 0MPa-0.5MPa | |||
Connection way | six tenths femate thread iner,six tenths male thread outlet | |||
Applicable medium | Water | |||
Valve body material | Copper valve body | |||
Medium temperature | 0-130oC | |||
Environment temperature | 0-40oC | |||
Rated voltage |
AC220V, AC110V, DC110V, AC24V, DC24V, AC12V, DC12V, DC9V | |||
Variable voltage of supply voltage | -10%~10% | |||
Insulation resitsance | Tested by DC500V megohmmete for 1 min, the insulation resistance should ≥100M | |||
Watertight performance |
Hydrostatic pressure 0.02Mpa, leakage ratio<0.1mL/min Hydrostatic pressure 0.03~0.8Mpa, leakage ratio 0mL/min | |||
Hydraulic pressure withstand | Withstand hydrostatic pressure of 1.2MPa for 5min, no unbroken, deformation or outside leakage | |||
Reliability | 0.01~0.02MPa,make and break for 10s respectively, lasting 1h, the check valve should be unblocked. | |||
Flow characteristics |
Pressure 0.02Mpa Flux >3L/min; Pressure 0.1Mpa Flux>8L/min; Pressure 0.3Mpa Flux >13L/min; Pressure 0.8Mpa Flux >25L/min | |||
Across layers insulation | Withstand high voltage pulse for 2s, it should be normal. | |||
Continuously energized | Energize for 12h, but not connect through the water, the valve should be no deformation, and the coil should not be burned; | |||
Withstand voltage | The acceptable high-voltage power between electric conduction and outer without electrified metal Withstand AC1500V,s50Hz for 1min, no flashover or breakdown; Withstand 1800V,50Hz for 1s, no flashover or breakdown; | |||
Non-return function | No | |||
Filtering function | Built-in filter screen | |||
Adjustment function | No | |||
Angle between coil and valve body | 360, 270, 180, 90 | |||
Power supply connection way | Lead Or Inserting type, adopting 6.3 plug spring.. |