MODEL |
NET-35C | |||
OUTPUT |
OUTPUT NUMBER |
CH1 |
CH2 |
CH3 |
DCVOLTAGE |
5V |
15V |
-15V | |
RATEDCURRENT |
2.5A |
1A |
0.5A | |
CURRENTRANGE |
0.5~3.5A |
0.1-1.5A |
0.1-0.5A | |
RATED POWER |
33W | |||
RIPPLE&NOISENOTE.2 |
80MVP-P |
150mVp-p |
150mVp-p | |
VOLTAGEADJ.RANGE |
CH1: 4.75~5.5V | |||
VOLTAGETOLERANCENOTE.3 |
±2.0% |
±6.0% |
±6.0% | |
LINEREGULATION |
±0.5% |
±1.0% |
±1.0% | |
LOADREGULATION |
±1.5% |
±3.0% |
±3.0% | |
SETUP.RISEHOLD.TIME |
500ms,30ms/230VAC ,1200ms, 30ms/115VAC at full load | |||
HOLD TIME |
50ms/230vac 10ms/115vac at full load | |||
INPUT |
VOLTAGERANGE |
85~264VAC 120~370VDC | ||
FREQUENCYRANGE |
47~63HZ | |||
EFFICIENCY |
79% | |||
AC CURRENT |
0.75a/115vac 0.5a/230vac | |||
INRUSH CURRENT |
Cold start 45A | |||
LEAKAGECURRENT |
<2mA/240VAC | |||
PROTECTION |
OVERLOAD |
Above 110~150%rated outputpower | ||
Protection type:Hiccup mode,recovers automatically after fault condition is removed | ||||
OVER VOLTAGE |
5.75~6.75V | |||
Protection type:Shut odown o/p voltage,re-power on to recover | ||||
ENVIRONMENT |
WORKINGTIMP |
-20~+60℃ | ||
WORKINGHUMIDITY |
20~90% RH non-condensing | |||
STORAGE TEMP HUMIDITY |
-40~+85℃ 10~95%RH | |||
TEMPCOEFFICIENT |
±0.03%(0~45℃) | |||
VIBRATION |
10~500HZ,2G10min/1cycle period for 60 min each alongX,Y,Zaxes | |||
SAFETY&EMC |
SAFETYSTANDARDS |
UL60950-1 Approved,CB Approved by TUV(design Refer to IEC 60950-1) | ||
WITHSTAND VOLTAGE |
1/P-0/P:3KVAC 1/P-FG:1.5KVAC 0/P-FG:0.5KVAC | |||
ISOLATIONRESISTANCE |
1/P-0/P,1/P-FG,0/P-FG:100M Ohms/500VDC | |||
EMI CONDUCTICN&
RADIATION |
Compliance to EN55022(CISPR22)classB | |||
HARMONICCURRENT |
Compliance to EN61000-3-2,-3 | |||
EMS IMMUNITY |
Compliance to EN61000-4-2,3,4,5,6,8,11 ENV50204,EN50204,EN61000-6-1 Light industry level criteriaA | |||
QTHERS |
MTBF |
386.2 Khrs min MIL-HDBK-217F(25℃) | ||
DIMENSION |
99*97*36mm(L*W*H) | |||
PACKING |
0.36Kg 45pcs / 17.2Kg / 0.9CUFT | |||
NOTE |
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Line regulation is measured from low line to high line at rated load.
5. Load regulation is measured from 0% to 100% rated load.
6. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
|