Model |
net-50b | |||
Output |
output number |
ch1 |
ch2 |
ch3 |
dcvoltage |
5v |
12v |
-12v | |
ratedcurrent |
4a |
2a |
0.5a | |
currentrange |
0.6~5a |
0.2-2.5a |
0.1-0.7a | |
rated power |
50w | |||
ripple&noisenote.2 |
80mvp-p |
120mvp-p |
120mvp-p | |
voltageadj.Range |
ch1: 4.75~5.5v | |||
voltagetolerancenote.3 |
±2.0% |
±6.0% |
±5.0% | |
lineregulation |
±0.5% |
±1.0% |
±1.0% | |
loadregulation |
±1.5% |
±3.0% |
±1.0% | |
setup.Risehold.Time |
500ms,30ms/230vac ,1200ms, 30ms/115vac at full load | |||
hold time |
50ms/230vac 10ms/115vac at full load | |||
Input |
voltagerange |
85~264vac 120~370vdc | ||
frequencyrange |
47~63hz | |||
efficiency |
78% | |||
ac current |
1.1a/115vac 1.65a/230vac | |||
inrush current |
cold start 45a | |||
leakagecurrent |
<2ma/240vac | |||
Protection |
overload |
above 110~150%rated outputpower | ||
protection type:hiccup mode,recovers automatically after fault condition is removed | ||||
over voltage |
ch1: 5.75~6.75v | |||
protection type:shut odown o/p voltage,re-power on to recover | ||||
Environment |
workingtimp |
-20~+60℃ | ||
workinghumidity |
20~90% rh non-condensing | |||
storage temp humidity |
-40~+85℃ 10~95%rh | |||
tempcoefficient |
±0.03%(0~45℃) | |||
vibration |
10~500hz,2g10min/1cycle period for 60 min each alongx,y,zaxes | |||
Safety&Emc |
safetystandards |
ul60950-1 approved,cb approved by tuv(design refer to iec 60950-1) | ||
withstand voltage |
1/p-0/p:3kvac 1/p-fg:1.5kvac 0/p-fg:0.5kvac | |||
isolationresistance |
1/p-0/p,1/p-fg,0/p-fg:100m ohms/500vdc | |||
emi conducticn&
radiation |
compliance to en55022(cispr22)classb | |||
harmoniccurrent |
compliance to en61000-3-2,-3 | |||
ems immunity |
compliance to en61000-4-2,3,4,5,6,8,11 env50204,en50204,en61000-6-1 light industry level criteriaa | |||
Qthers |
mtbf |
348.4 khrs min mil-hdbk-217f(25℃) | ||
dimension |
129*98*38mm(l*w*h) | |||
packing |
0.44kg 30pcs / 14.2kg / 0.72cuft | |||
Note |
1. All parameters not specially mentioned are measured at 230vac input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20mhz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Line regulation is measured from low line to high line at rated load.
5. Load regulation is measured from 0% to 100% rated load.
6. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
emc directives.
|