Product Main

Specifications

LC Series oval gear flow meter, the main type of positive displacement flow meters, is used to measure pressure in the pipeline closed under full pipe flow of the fluid flow. It has high accuracy, reliability, long life and wide range, small pressure loss, viscosity and good adaptation, is essentially unregulated measuring temperature, pressure change, and ease of installation. Petroleum products mainly used for measuring the cumulative flow, can also be used for other chemical solution (except the corrosive agents) measurement. Direct Reading of the flowmeter accumulated fluid-flow meters, is equipped with a pair of oval gear switched from the measurement chamber, sealed coupling (a small-caliber flowmeter high sensitivity magnetic coupling) and technical institutions

Basic error limit
±0.5
Nominal pressureMPa
1.6
Working temperature
-30-+160
Liquid viscositymPas
0.6-200
Type
Inside nominal diameter(mm)
 
Flow ratem2/ h
Viscosity of oil productmPas
Chemical liquid viscositym2/ h
0.6-2
2-8
8-200
0.6-200
LC-10
10
0.15-0.4
0.08-0.4
0.04-0.4
0.1-0.4
LC-15
15
0.38-1.5
0.25-1.5
0.15-1.5
0.3-1.5
LC-20
20
0.75-3
0.4-3
0.3-3
0.6-3
LC-25
25
1.5-6
0.8-6
0.6-6
1.2-6
LC-40
40
3-15
2-15
1.5-15
2.4-12
LC-50
50
4.8-24
3.2-24
2.4-24
3.8-19
LC-80
80
12-60
8-60
6-60
10-50
LC-100
100
20-100
13-100
10-100
16-80