Applications 1. Gas laser, DC HV power supplies, HV dividers, HV generators. 2. Lightning arresters voltage distribution systems. 3. Electron microscopes, synchroscopes. 4. Electrostatic coating machines.
Part No. |
Capacitance (pF) |
Capacitance Tolerance (%) |
Rated Voltage (kVDC) |
Dimension (mm) |
Terminal Type | ||
φD |
L |
H | |||||
CTU-10-561 |
560 |
±10 |
10 |
24 |
20 |
18 |
M4×4 |
CTU-10-122 |
1200 |
30 |
20 |
18 | |||
CTU-10-282 |
2800 |
40 |
20 |
18 | |||
CTU-10-502 |
5000 |
52 |
20 |
18 |
M5×4 | ||
CTU-10-802 |
8000 |
60 |
16 |
14 | |||
CTU-20-281 |
280 |
20 |
24 |
26 |
24 |
M4×4 | |
CTU-20-881 |
880 |
30 |
26 |
24 | |||
CTU-20-142 |
1400 |
40 |
26 |
24 | |||
CTU-20-252 |
2500 |
52 |
26 |
24 |
M5×4 | ||
CTU-20-402 |
4000 |
60 |
26 |
24 | |||
CTU-30-591 |
590 |
30 |
30 |
30 |
28 |
M4×4 | |
CTU-30-941 |
940 |
40 |
30 |
28 | |||
CTU30-172 |
1700 |
52 |
30 |
28 |
M5×4 | ||
CTU-30-272 |
2700 |
60 |
30 |
28 | |||
CTU-40-441 |
440 |
40 |
30 |
32 |
30 |
M4×4 | |
CTU-40-701 |
700 |
40 |
32 |
30 | |||
CTU-40-132 |
1300 |
52 |
32 |
30 |
M5×4 | ||
CTU-40-202 |
2000 |
60 |
32 |
30 | |||
CTU-50-401 |
400 |
50 |
30 |
35 |
33 |
M4×4 | |
CTU-50-651 |
650 |
36 |
35 |
33 | |||
CTU-50-911 |
910 |
40 |
33 |
31 | |||
CTU-50-112 |
1100 |
52 |
35 |
33 |
M5×4 |
-
No.
Item
Specifications
Testing method
1
Operating Temp.Range
-20℃~-+85℃
——
2
Capacitance
Within the specified Tolerance
Measured at 25℃ with 1± 0.1kHz and 1V (rms)
3
Temperature Characteristics
D N4700
Compared with the Value measured at 25℃, The capacitance change from -25℃ to 85℃ should not exceed the limit specified.
4
Dissipation Factor
≤0.3%
The same as No.2
5
Withstand voltage
No failure
Applied 1.5 times of rated voltage for 60 second.
6
Insulation Resistance(I.R.)
>104MW
Measured with DC 1kV within 60±5sec.
7
Life
Appearance
No marked defect
Capacitance change
whthin±20%
D.R.
≤5%
I.R.
1000 MΩmin.
Apply a DC voltage of 125% of the rated voltage for 100+24/-0 hrs. In silicon oil at 85±2℃. Post treatment: Capacitor should be stored for 24 hrs. At room condition.(Charge/Discharge current≤50mA)
8
Humidity (under Steady State)
Appearance
No marked defect
capacitance change
within±20%
D.R.
≤5%
I.R.
1000 MΩmin.
Set the capacitor for 100-0+24 hrs at 40±2℃ in 90 to 95% relative humidity. Post-treatment: Capacitor should be stored for 24 hrs.At room conditi