Product Main

Specifications

Product Description

Plate: In the ordinary circumstances suggested the Bolivian magnesium board does with the 6MM thickness above separates the wall plate. Fitting: Above the 6MM plate fixes on the frame keel, must use 3. 520MM to sink a screw retention, the nail head is lower than the pan 0. 5MM, in order to the guarantee facing is smooth. Installment: Starts when installs, must the sign good keel standard position, and finishes the symbol, the center keel center distance be 45. - 600MM, the wall attachment point and the windows and doors two sides install when must install attaches the keel, when highly like the wall is bigger than 2440MM, must Installs in the plate attachment point supports the keel. Board distance: Is near between the plate to keep the seam to be apart from 4-6MM. Between the plate and the ground must the 5MM gap, the bolt installment center The distance is 150MM, is apart from flange 10MM, is away from board angle 30MM. Hangs: Between the hygienic once in a while kitchen and so on hangs the heavy item place, must use the plank or the keel reinforcement, in order to avoid the plate receives the destruction. Joint processing: When installment the plate and the plate gap 4 - 6MM, mixes well after 107 glue water or the force rubber spreads with the shaving knife Wipes the plate and the slit place, then glues with the paper tape or the style belt presses evenly. Coating decoration: May use to spurt spreads, or rolls spreads, when brushes spreads must refer to the coating the related explanation. Installs the facing to paste the ceramic tile: When the bathroom, the bathroom, the kitchen, the basement wait for tide wet region installs, like must paste the ceramic tile in the pan Between the keel distance must reduce to 400MM. The strong body each three blocks (about 3. 6MM must approximately) an expansion and contraction Seam. Separates the intensity of sound body: Like needs the strong body to have the high sound-insulated effect, must request the strong body and the plate union close is airtight, again approaches the spatial wall In fills the asbestos, when like keel both sides use two kind of different thickness the boards, the sound-insulated effect is better. Anti- impact wall: Suggested you select above 8MM the board or add plywood, the second board must use the long some screw bolt reinforcement. This method may strengthen the anti- impact, the heat insulation, the sound-insulated effect and the fire protection performance.