Product Main

Specifications

Technical performance indicators
3.1 implementation of the standards: JB / T 9248-1999 electromagnetic flow meter.
3.2 electrode materials: 316L; Hc; Hb; Ti; Ta.
3.3 lining materials: polyurethane rubber; chloroprene rubber; F46; PTFE; PFA.
3.4 Media: conductive liquid (including the solid-liquid two-phase).
3.5 measurement error: ± 0.2%; ± 0.5%; ± 1.0% flow (in diameter).
3.6 medium conductivity: > 5uS/cm.
3.7 speed range: 0.3 ~ 12m/s
3.8 Rated pressure: 0.6MPa ~ 42MPa (in accordance with sub-caliber).
3.9 flange connection: GB/T9115.1-2000
3.10 level of protection: IP65; IP67; IP68 (split).
3.11 Communications: RS485
3.12: Display: instantaneous flow; velocity; positive cumulative flow; reverse cumulative flow; percentage;
3.13 Language: Chinese / English
3.14 Power supply: 220VAC; 24VDC
3.15 installed in the form of: all-in-one or split
3.16 explosion-proof certification: EXme T6
3.17 output signal: 0 ~ 10mA or 4 ~ 20mA; frequency / pulse output
3.18 current output load resistance: 0 ~ 1.5kΩ when 0 ~ 10mA; 0 ~ 750Ω when 4 ~ 20mA.